Determination of retigabine and its acetyl metabolite in biological matrices by on-line solid-phase extraction (column switching) liquid chromatography with tandem mass spectrometry

被引:31
作者
Knebel, NG [1 ]
Grieb, S [1 ]
Leisenheimer, S [1 ]
Locher, M [1 ]
机构
[1] ASTA Med AG, Dept Biol Res Biochem, D-60314 Frankfurt, Germany
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 748卷 / 01期
关键词
retigabine;
D O I
10.1016/S0378-4347(00)00272-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A HPLC assay with tandem mass spectrometric detection in the positive-ion atmospheric pressure chemical ionisation (APCI) mode for the sensitive determination of retigabine [(I), D-23129] and its acetyl metabolite [(II), ADW 21-360] in plasma was developed, utilising the structural analogue (D-10328), (III), as internal standard. Automated on-line solid-phase extraction of diluted plasma samples, based on 200-mul plasma aliquots, at pH 6.5, allowed a reliable quantification of retigabine and the acetyl metabolite down to 1 ng/ml. Injection of 500 mul of diluted plasma onto a C-2 stationary phase-based column switching system in combination with a 75 mmx4 mm reversed-phase analytical column at a flow-rate of 0.5 ml/min provided cycle times of 4 min per sample. The standard curves were linear from 1 to 1000 ng/ml using weighted linear regression analysis (1/x(2)). The method is accurate (mean accuracy less than or equal to+/-10%), precise (RSD <+15%) and sensitive, providing lower limits of quantification in plasma of 1 ng/ml for retigabine (I), and 2.5 ng/ml for the metabolite (II) with limits of detection of 0.5 ng/ml for both analytes. Up to 200 unknowns may be analysed each 24 h per analyst. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:97 / 111
页数:15
相关论文
共 23 条
  • [1] Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
  • [2] 2-Q
  • [3] Use of generic fast gradient liquid chromatography tandem mass spectroscopy in quantitative bioanalysis
    Ayrton, J
    Dear, GJ
    Leavens, WJ
    Mallett, DN
    Plumb, RS
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02): : 243 - 254
  • [4] Barron D, 1996, J MASS SPECTROM, V31, P309, DOI 10.1002/(SICI)1096-9888(199603)31:3<309::AID-JMS298>3.0.CO
  • [5] 2-6
  • [6] Progress report on new antiepileptic drugs: A summary of the Third Eilat Conference
    Bialer, M
    Johannessen, SI
    Kupferberg, HJ
    Levy, RH
    Loiseau, P
    Perucca, E
    [J]. EPILEPSY RESEARCH, 1996, 25 (03) : 299 - 319
  • [7] ANTICONVULSANT PROPERTIES OF D-20443 IN GENETICALLY EPILEPSY-PRONE RATS - PREDICTION OF CLINICAL-RESPONSE
    DAILEY, JW
    CHEONG, JH
    KO, KH
    ADAMSCURTIS, LE
    JOBE, PC
    [J]. NEUROSCIENCE LETTERS, 1995, 195 (02) : 77 - 80
  • [8] Hempel R, 1999, DRUG METAB DISPOS, V27, P613
  • [9] Sample preparation for LC/MS/MS: Analyzing biological and environmental samples
    Henion, J
    Brewer, E
    Rule, G
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (19) : 650A - 656A
  • [10] ION-SPRAY MASS-SPECTROMETRIC DETECTION FOR LIQUID-CHROMATOGRAPHY - A CONCENTRATION-FLOW-SENSITIVE OR A MASS-FLOW-SENSITIVE DEVICE
    HOPFGARTNER, G
    BEAN, K
    HENION, J
    HENRY, R
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 647 (01): : 51 - 61