A Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac Electrophysiology

被引:302
作者
Viventi, Jonathan [3 ]
Kim, Dae-Hyeong [1 ,2 ]
Moss, Joshua D. [4 ]
Kim, Yun-Soung [1 ,2 ]
Blanco, Justin A. [3 ]
Annetta, Nicholas [5 ]
Hicks, Andrew [3 ]
Xiao, Jianliang [6 ,7 ]
Huang, Younggang [6 ,7 ]
Callans, David J. [4 ]
Rogers, John A. [1 ,2 ]
Litt, Brian [3 ,8 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Frederick Seitz Mat Res Lab, Urbana, IL 61801 USA
[3] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[4] Hosp Univ Penn, Dept Med, Div Cardiol, Philadelphia, PA 19104 USA
[5] Univ Penn, Dept Elect & Syst Engn, Philadelphia, PA 19104 USA
[6] Northwestern Univ, Dept Mech Engn, Evanston, IL 60208 USA
[7] Northwestern Univ, Dept Civil & Environm Engn, Evanston, IL 60208 USA
[8] Hosp Univ Penn, Dept Neurol, Penn Epilepsy Ctr, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
INTEGRATED-CIRCUITS; ARRAYS;
D O I
10.1126/scitranslmed.3000738
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
In all current implantable medical devices such as pacemakers, deep brain stimulators, and epilepsy treatment devices, each electrode is independently connected to separate control systems. The ability of these devices to sample and stimulate tissues is hindered by this configuration and by the rigid, planar nature of the electronics and the electrode-tissue interfaces. Here, we report the development of a class of mechanically flexible silicon electronics for multiplexed measurement of signals in an intimate, conformal integrated mode on the dynamic, three-dimensional surfaces of soft tissues in the human body. We demonstrate this technology in sensor systems composed of 2016 silicon nanomembrane transistors configured to record electrical activity directly from the curved, wet surface of a beating porcine heart in vivo. The devices sample with simultaneous submillimeter and submillisecond resolution through 288 amplified and multiplexed channels. We use this system to map the spread of spontaneous and paced ventricular depolarization in real time, at high resolution, on the epicardial surface in a porcine animal model. This demonstration is one example of many possible uses of this technology in minimally invasive medical devices.
引用
收藏
页数:9
相关论文
共 23 条
[1]   Nanoindentation testing of SU-8 photoresist mechanical properties [J].
Al-Halhouji, A. T. ;
Kampen, I. ;
Krah, T. ;
Buettgenbach, S. .
MICROELECTRONIC ENGINEERING, 2008, 85 (5-6) :942-944
[2]   EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias [J].
Aliot, Etienne M. ;
Stevenson, William G. ;
Almendral-Garrote, Jesus Ma ;
Bogun, Frank ;
Calkins, C. Hugh ;
Delacretaz, Etienne ;
Della Bella, Paolo ;
Hindricks, Gerhard ;
Jais, Pierre ;
Josephson, Mark E. ;
Kautzner, Josef ;
Kay, G. Neal ;
Kuck, Karl-Heinz ;
Lerman, Bruce B. ;
Marchlinski, Francis ;
Reddy, Vivek ;
Schalij, Martin-Jan ;
Schilling, Richard ;
Soejima, Kyoko ;
Wilber, David .
EUROPACE, 2009, 11 (06) :771-817
[3]   Semiconductor wires and ribbons for high-performance flexible electronics [J].
Baca, Alfred J. ;
Ahn, Jong-Hyun ;
Sun, Yugang ;
Meitl, Matthew A. ;
Menard, Etienne ;
Kim, Hoon-Sik ;
Choi, Won Mook ;
Kim, Dae-Hyeong ;
Huang, Young ;
Rogers, John A. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (30) :5524-5542
[4]   A 13.56-MHz RFID system based on organic transponders [J].
Cantatore, Eugenio ;
Geuns, Thomas C. T. ;
Gelinck, Gerwin H. ;
van Veenendaal, Erik ;
Gruijthuijsen, Arnold F. A. ;
Schrijnemakers, Laurens ;
Drews, Steffen ;
de Leeuw, Dago M. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2007, 42 (01) :84-92
[5]   DIRECT MEASUREMENT OF INTERFACIAL INTERACTIONS BETWEEN SEMISPHERICAL LENSES AND FLAT SHEETS OF POLY(DIMETHYLSILOXANE) AND THEIR CHEMICAL DERIVATIVES [J].
CHAUDHURY, MK ;
WHITESIDES, GM .
LANGMUIR, 1991, 7 (05) :1013-1025
[6]   DIRECTIONAL DIFFERENCES OF IMPULSE SPREAD IN TRABECULAR MUSCLE FROM MAMMALIAN HEART [J].
CLERC, L .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 255 (02) :335-346
[7]   Flexible active-matrix displays and shift registers based on solution-processed organic transistors [J].
Gelinck, GH ;
Huitema, HEA ;
Van Veenendaal, E ;
Cantatore, E ;
Schrijnemakers, L ;
Van der Putten, JBPH ;
Geuns, TCT ;
Beenhakkers, M ;
Giesbers, JB ;
Huisman, BH ;
Meijer, EJ ;
Benito, EM ;
Touwslager, FJ ;
Marsman, AW ;
Van Rens, BJE ;
De Leeuw, DM .
NATURE MATERIALS, 2004, 3 (02) :106-110
[8]   INTERACTION OF FIBER ORIENTATION AND DIRECTION OF IMPULSE PROPAGATION WITH ANATOMIC BARRIERS IN ANISOTROPIC CANINE MYOCARDIUM [J].
KADISH, A ;
SHINNAR, M ;
MOORE, EN ;
LEVINE, JH ;
BALKE, CW ;
SPEAR, JF .
CIRCULATION, 1988, 78 (06) :1478-1494
[9]   A stretchable form of single-crystal silicon for high-performance electronics on rubber substrates [J].
Khang, DY ;
Jiang, HQ ;
Huang, Y ;
Rogers, JA .
SCIENCE, 2006, 311 (5758) :208-212
[10]   Stretchable and foldable silicon integrated circuits [J].
Kim, Dae-Hyeong ;
Ahn, Jong-Hyun ;
Choi, Won Mook ;
Kim, Hoon-Sik ;
Kim, Tae-Ho ;
Song, Jizhou ;
Huang, Yonggang Y. ;
Liu, Zhuangjian ;
Lu, Chun ;
Rogers, John A. .
SCIENCE, 2008, 320 (5875) :507-511