Room temperature ionic liquid carbon nanotube paste electrodes: Overcoming large capacitive currents using rotating disk electrodes

被引:55
作者
Kachoosangi, Roohollah Torabi [1 ]
Wildgoose, Gregory G. [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
room temperature ionic liquid; carbon nanotube; paste electrode; rotating disk electrode; voltammetry;
D O I
10.1002/elan.200703883
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The voltammetric response of graphite or carbon nanotube paste electrodes, which incorporate the room temperature ionic liquid, N-butyl-N-methyl pyrrolidinium bis(trifluoromethylsulfonyl) imide or [C(4)mpyrr][NTf2], (RTIL-CNTPE and RTIL-CPE respectively) as the binder, towards anionic, cationic and neutral redox probes is examined and compared to conventional paste electrodes which use mineral oil as the binder. The RTIL paste electrodes are found to suffer from very large background currents due to capacitive charging. This is exacerbated further when CNTs are combined with RTILs in the paste. The large charging currents obscure any Faradaic processes of interest, especially at low analyte concentrations. By employing steady state voltammetry at a rotating disk electrode made of the RTIL pastes this problem can be overcome. This allows the electroanalytical properties of these interesting electrode substrates, which combine the attractive properties of CNTs with RTILs to be further explored and developed.
引用
收藏
页码:1483 / 1489
页数:7
相关论文
共 53 条
[1]   Carbon nanotube composite coated platinum electrode for detection of Cr(III) in real samples [J].
Abbaspour, Abdolkarim ;
Izadyar, Anahita .
TALANTA, 2007, 71 (02) :887-892
[2]   CARBON PASTE ELECTRODES [J].
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1958, 30 (09) :1576-1576
[3]   Alcohol biosensor based on the immobilization of meldola blue and alcohol dehydrogenase into a carbon nanotube paste electrode [J].
Antiochia, R ;
Lavagnini, I .
ANALYTICAL LETTERS, 2006, 39 (08) :1643-1655
[4]   Amperometric mediated carbon nanotube paste biosensor for fructose determination [J].
Antiochia, R ;
Lavagnini, I ;
Magno, F .
ANALYTICAL LETTERS, 2004, 37 (08) :1657-1669
[5]   Carbon nanotubes contain metal impurities which are responsible for the "electrocatalysis" seen at some nanotube-modified electrodes [J].
Banks, CE ;
Crossley, A ;
Salter, C ;
Wilkins, SJ ;
Compton, RG .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (16) :2533-2537
[6]   New electrodes for old: from carbon nanotubes to edge plane pyrolytic graphite [J].
Banks, CE ;
Compton, RG .
ANALYST, 2006, 131 (01) :15-21
[7]   The transport limited currents at insonated electrodes [J].
Banks, CE ;
Compton, RG ;
Fisher, AC ;
Henley, LE .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2004, 6 (12) :3147-3152
[8]   Sonoelectrochemistry in acoustically emulsified media [J].
Banks, CE ;
Rees, NV ;
Compton, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 535 (1-2) :41-47
[9]  
CHAUVIN Y, 1995, CHEMTECH, V25, P26
[10]   Carbon nanotubes paste electrodes as new detectors for capillary electrophoresis [J].
Chicharro, M ;
Sánchez, A ;
Bermejo, E ;
Zapardiel, A ;
Rubianes, MD ;
Rivas, GA .
ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) :84-91