Accuracy of amplitude integrated EEG in a neonatal cohort

被引:52
作者
Evans, E. [1 ,2 ]
Koh, S. [4 ]
Lerner, J. T. [3 ]
Sankar, R. [3 ]
Garg, M. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Div Neonatol & Dev Biol, Dept Pediat, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Neonatal Res Ctr, Dept Pediat, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Div Pediat Neurol, Dept Pediat, Los Angeles, CA 90095 USA
[4] Univ Colorado, Sch Med, Childrens Hosp, Div Pediat Neurol, Denver, CO USA
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2010年 / 95卷 / 03期
关键词
CEREBRAL FUNCTION MONITOR; SEIZURES; BRAIN; ELECTROENCEPHALOGRAPHY; ENCEPHALOPATHY; INFANTS; DEVICE;
D O I
10.1136/adc.2009.165969
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective To determine the sensitivity and specificity of amplitude integrated electroencephalogram (aEEG) compared to simultaneous standard electroencephalogram (sEEG) for seizure detection and background discontinuity. Design Prospective paired cohort. Setting Tertiary academic neonatal intensive care unit. Patients Infants were recruited from 2005 to 2008. Neonates requiring sEEG were recruited for simultaneous aEEG. Interventions Following sEEG and aEEG, seizures were recorded as present or absent, and background was recorded as normal or discontinuous in each format. Main outcome measures Presence of at least one seizure during recording. The background activity was reported as normal or discontinuous. Discontinuity of brain activity was further ranked as mild, moderate or severe. Results 51 sEEG and aEEG studies were completed. 44 studies were analysed for presence of seizures and 46 were analysed for background discontinuity. Sensitivity for presence of seizures by aEEG was 80% and specificity was 50%. The proportion of infants with seizures were overdiagnosed by aEEG (63.6% vs 45.5% for sEEG p=0.045). Discontinuity of background activity had higher sensitivity (88.6%) and specificity (54.5%) when compared with seizure detection. When stratified by indication for EEG, hypoxic episode (n=14) or suspected seizures (n=33), similar sensitivity for presence of seizure (80%) was noted by aEEG and sEEG. However the specificity of aEEG for seizure detection was higher in neonates undergoing EEG for suspected seizures (66.7% vs 22.2%). Conclusions Background abnormalities were detected with fair accuracy by aEEG but aEEG criteria alone would result in the overdiagnosis of neonatal seizures. Therefore seizures noted on aEEG require sEEG confirmation prior to implementing anticonvulsant therapy for neonatal seizures.
引用
收藏
页码:F169 / F173
页数:5
相关论文
共 38 条
[21]   Seizure-associated brain injury in term newborns with perinatal asphyxia [J].
Miller, SP ;
Weiss, J ;
Barnwell, A ;
Ferriero, DM ;
Latal-Hajnal, B ;
Ferrer-Rogers, A ;
Newton, N ;
Partridge, JC ;
Glidden, DV ;
Vigneron, DB ;
Barkovich, AJ .
NEUROLOGY, 2002, 58 (04) :542-548
[22]  
Mizrahi E M, 1987, Epilepsia, V28 Suppl 1, pS46, DOI 10.1111/j.1528-1157.1987.tb05757.x
[23]  
MIZRAHI EM, 1989, CLEV CLIN J MED, V56, pS100
[24]   Acute and chronic effects of seizures in the developing brain: Lessons from clinical experience [J].
Mizrahi, EM .
EPILEPSIA, 1999, 40 :S42-S50
[25]   Non-expert use of the cerebral function monitor for neonatal seizure detection [J].
Rennie, JM ;
Chorley, G ;
Boylan, GB ;
Pressler, R ;
Nguyen, Y ;
Hooper, R .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2004, 89 (01) :F37-F40
[26]   The physiological basis for continuous electroencephalogram monitoring in the neonate [J].
Rosen, Ingmar .
CLINICS IN PERINATOLOGY, 2006, 33 (03) :593-+
[27]   Do seizures affect the developing brain? Lessons from the laboratory [J].
Sankar, Raman ;
Rho, Jong M. .
JOURNAL OF CHILD NEUROLOGY, 2007, 22 (05) :21S-29S
[28]   Amplitude-integrated electroencephalography in the newborn:: A valuable tool [J].
Shah, Divyen K. ;
de Vries, Linda S. ;
Hellstrom-Westas, Lena ;
Toet, Mona C. ;
Inder, Terrie E. .
PEDIATRICS, 2008, 122 (04) :863-865
[29]   Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants [J].
Shah, Divyen K. ;
Mackay, Mark T. ;
Lavery, Shelly ;
Watson, Susan ;
Harvey, A. Simon ;
Zempel, John ;
Mathur, Amit ;
Inder, Terrie E. .
PEDIATRICS, 2008, 121 (06) :1146-1154
[30]   Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection [J].
Shellhaas, Renee A. ;
Soaita, Adina I. ;
Clancy, Robert R. .
PEDIATRICS, 2007, 120 (04) :770-777