Cemented Rotating-Platform Total Knee Replacement

被引:56
作者
Callaghan, John J.
Wells, Christopher W.
Liu, Steve S.
Goetz, Devon D.
Johnston, Richard C.
机构
[1] Univ Iowa, Coll Med, Iowa City, IA USA
[2] Iowa Methodist Hosp, Des Moines, IA USA
关键词
20-YEAR FOLLOW-UP; MENISCAL BEARING; ARTHROPLASTY; COMPONENTS; SURVIVAL; SYSTEM; WEAR;
D O I
10.2106/JBJS.I.01012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
We previously evaluated 119 consecutive total knee arthroplasties performed by a single surgeon in eighty-six patients with use of the cemented LCS (low contact stress) mobile-bearing, rotating-platform system and an allpolyethylene patellar component. The average age of the patients at the time of surgery was seventy years. The patients were contacted as part of their routine follow-up and were asked to participate in this study. The purpose of the present study was to report the updated results at a minimum follow-up of twenty years. Twenty patients (twenty-six knees) were living, and one was lost to follow-up. Three knees required a reoperation (two for periprosthetic fractures and one for infection). No component was revised as a part of the reoperations. No knee required revision since the fifteen-year follow-up evaluation. Osteolysis was present in six knees compared with only three knees at the time of the fifteen-year follow-up. One knee had radiographic signs of femoral component loosening, which was associated with osteolysis. It occurred after the fifteen-year follow-up study. The average range of motion was from 1 of extension to 105 degrees of flexion. The average clinical and functional Knee Society scores were 43 and 49 points, respectively, at the preoperative evaluation and 89 and 67 points at the time of the final follow-up. We concluded that the cemented LCS rotating-platform knee performed well, with durable clinical and radiographic results at a minimum follow-up of twenty years. However, the prevalence of osteolysis continues to increase with a longer duration of follow-up in these patients.
引用
收藏
页码:1635 / 1639
页数:5
相关论文
共 24 条
[1]
POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[2]
THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[3]
Bellamy N, 1995, W ONTARIO MCMASTER U, P14
[4]
BERT JM, 1990, CLIN ORTHOP RELAT R, P211
[5]
Buechel FF, 2001, CLIN ORTHOP RELAT R, P41
[6]
BUECHEL FF, 1990, CLIN ORTHOP RELAT R, P162
[7]
THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[8]
Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[9]
Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report [J].
Callaghan, JJ ;
O'Rourke, MR ;
Iossi, MF ;
Liu, SS ;
Goetz, DD ;
Vittetoe, DA ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :1995-1998
[10]
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9