Toward metrological traceability for DNA fragment ratios in GM quantification. 3. Suitability of DNA calibrants studied with a MON 810 corn model

被引:27
作者
Charels, Diana [1 ]
Broeders, Sylvia [1 ]
Corbisier, Philippe [1 ]
Trapmann, Stefanie [1 ]
Schimmel, Heinz [1 ]
Emons, Hendrik [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
Certified Reference Material; CRM; genetically modified organism; GMO; DNA calibrant; calibration; plasmid; real-time PCR; PCR efficiency; measurement uncertainty;
D O I
10.1021/jf0629336
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The quantification of GMOs by real-time PCR relies on an external calibrant. In this paper the suitability of two DNA calibrants, genomic DNA from plant leaves and plasmidic DNA, was investigated. The PCR efficiencies, the correlation coefficients of the calibration curves, and the ratios between PCR efficiencies of transgenic and endogenous sequences were compared for both calibrants using 59 data sets produced by 43 laboratories. There were no significant differences between plasmidic and genomic DNA except for the PCR efficiencies of the calibration curves for the transgene of the construct-specific real-time PCR method. In the GM system investigated, PCR efficiencies of plasmidic calibrants were slightly closer to the PCR efficiencies observed for the unknowns than those of the genomic DNA calibrant. Therefore, plasmidic DNA was the more suitable calibrant for the PCR measurements on genomic DNA extracted from MON 810 seeds. It is shown that plasmidic DNA is an appropriate choice for the calibration of measurements of MON 810 corn with respect to the DNA copy number ratio.
引用
收藏
页码:3268 / 3274
页数:7
相关论文
共 21 条
[11]  
ISO (International Organization for Standardization), 2005, 21570 ISO
[12]   Determination of PCR efficiency in chelex-100 purified clinical samples and comparison of real-time quantitative PCR and conventional PCR for detection of Chlamydia pneumoniae [J].
Mygind, Tina ;
Birkelund, Svend ;
Birkebaek, Niels H. ;
Ostergaard, Lars ;
Jensen, Jorgen Skov ;
Christiansen, Gunna .
BMC MICROBIOLOGY, 2002, 2 (1) :1-8
[13]   Potential influence of the first PCR cycles in real-time comparative gene quantifications [J].
Nogva, HK ;
Rudi, K .
BIOTECHNIQUES, 2004, 37 (02) :246-+
[14]   Real Time Polymerase Chain Reaction (PCR) quantification of T25 maize seeds - influence of the genetic structures in the maize kernel on the quantitative analysis [J].
Papazova, N. ;
Taverniers, I. ;
Degrieck, I. ;
Van Bockstaele, E. ;
Joost, H. ;
De Loose, M. .
SEED SCIENCE AND TECHNOLOGY, 2006, 34 (02) :307-317
[15]  
Pietsch K, 1997, DEUT LEBENSM-RUNDSCH, V93, P35
[16]   Mathematics of quantitative kinetic PCR and the application of standard curves -: art. no. e93 [J].
Rutledge, RG ;
Côté, C .
NUCLEIC ACIDS RESEARCH, 2003, 31 (16)
[17]   DYNAMICS OF MAIZE ENDOSPERM DEVELOPMENT AND DNA ENDOREDUPLICATION [J].
SCHWEIZER, L ;
YERKDAVIS, GL ;
PHILLIPS, RL ;
SRIENC, F ;
JONES, RJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (15) :7070-7074
[18]  
Shindo Y, 2002, J AOAC INT, V85, P1119
[19]   Event-specific plasmid standards and real-time PCR methods for transgenic Bt11, Bt176, and GA21 maize and transgenic GT73 canola [J].
Taverniers, I ;
Windels, P ;
Vaïtilingom, M ;
Milcamps, A ;
Van Bockstaele, E ;
Van den Eede, G ;
De Loose, M .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (08) :3041-3052
[20]  
TRAPMANN S, 2005, 21574 IRMM EUR OFF O