Inter-observer and intra-observer reliability of mechanical axis alignment before and after total knee arthroplasty using long leg radiographs

被引:43
作者
Bowman, Anneka [1 ,2 ]
Shunmugam, Meenalochani [1 ]
Watts, Amy R. [1 ,2 ]
Bramwell, Donald C. [1 ,2 ]
Wilson, Christopher [1 ,2 ]
Krishnan, Jeganath [1 ,2 ]
机构
[1] Flinders Univ S Australia, Sch Med, Dept Orthopaed, Adelaide, SA 5001, Australia
[2] Repatriat Gen Hosp, Int Musculoskeletal Res Inst, Daws Rd, Daw Pk, SA 5041, Australia
关键词
Long leg radiograph; Alignment; Inter-observer reliability; Intra-observer reliability; Total knee arthroplasty; LOWER-EXTREMITY ALIGNMENT; CHEST RADIOGRAPHY; OSTEOARTHRITIS; EXPERIENCE; ROTATION; DISEASE; PACS;
D O I
10.1016/j.knee.2015.11.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Long leg radiographs (LLRs) are commonly performed for assessment of mechanical alignment and operative planning in patients undergoing total knee arthroplasty (TKA). The aim of this study was to determine the inter- and intra-observer reliability of alignment measured by observers of different levels of experience. Methods: Forty patients on the waiting list for a WA had pre- and post-operative standardised LLRs. We analysed the measurements of mechanical axis alignment between an orthopaedic surgeon, a senior orthopaedic registrar, a junior orthopaedic registrar, and a medical student. Reviewers performed blinded measurements on the same computer screen. These measurements were repeated three months later to assess intra-observer reliability. Furthermore high-resolution screens were compared with standard hospital computer screens to investigate whether monitoring quality influenced the accuracy of measurements of alignment. Results: Inter-observer reliability was high for pre-operative LLRs with an intra-class correlation (ICC) of > 0.9 at all experience levels. Post-operative ICC was lowest between the surgeon and the medical student at 0.7. Intraobserver reliability was high at all experience levels. Larger deformities appeared to have exaggerated measurements for both pre- and post -operative images. There appeared to be no effect of the monitor size and quality on the accuracy of measurement. Conclusions: Long leg radiographs can be used to measure mechanical axis alignment with strong reliability across different levels of experience. This information is important for the evaluation of knee alignment measurements in current clinical practice, to assess severity of deformity and to accompany pre-operative planning and post-operative evaluation. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 27 条
[1]
Al-Shawi A.K., 2005, Clinical Governance: An International Journal, V10, P212, DOI DOI 10.1108/14777270510612857
[2]
Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: An observer preference study [J].
Balassy, C ;
Prokop, M ;
Weber, M ;
Sailer, J ;
Herold, CJ ;
Schaefer-Prokop, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) :752-756
[3]
Balint G, 1996, DRUGS, V52, P1
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
The whole leg radiograph - Standing versus supine for determining axial alignment [J].
Brouwer, RW ;
Jakma, TSC ;
Bierma-Zeinstra, SMA ;
Ginai, AZ ;
Verhaar, JAN .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (05) :565-568
[6]
Effective measurement of knee alignment using AP knee radiographs [J].
Colebatch, Alexandra N. ;
Hart, Deborah J. ;
Zhai, Guangju ;
Williams, F. M. ;
Spector, Tim D. ;
Arden, Nigel K. .
KNEE, 2009, 16 (01) :42-45
[7]
Optimizing Limb Position for Measuring Knee Anatomical Axis Alignment from Standing Knee Radiographs [J].
Cooke, T. Derek V. ;
Sled, Elizabeth A. .
JOURNAL OF RHEUMATOLOGY, 2009, 36 (03) :472-477
[8]
Interobserver and Intraobserver Reliability in the Evaluation of Mechanical Axis Deviation [J].
Gordon, J. Eric ;
Chen, Ryan C. ;
Dobbs, Matthew B. ;
Luhmann, Scott J. ;
Rich, Margaret M. ;
Schoenecker, Perry L. .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2009, 29 (03) :281-284
[9]
Role of Alignment and Biomechanics in Osteoarthritis and Implications for Imaging [J].
Hunter, David J. ;
Wilson, David R. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (04) :553-+
[10]
Insights from Imaging on the Epidemiology and Pathophysiology of Osteoarthritis [J].
Hunter, David J. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (04) :539-+