Pre-storage of liquid reagents in glass ampoules for DNA extraction on a fully integrated lab-on-a-chip cartridge

被引:55
作者
Hoffmann, Jochen [2 ]
Mark, Daniel [1 ]
Lutz, Sascha [1 ]
Zengerle, Roland [1 ,2 ,3 ]
von Stetten, Felix [1 ,2 ]
机构
[1] HSG IMIT, D-78052 Villingen Schwenningen, Germany
[2] Univ Freiburg, Dept Microsyst Engn IMTEK, Lab MEMS Applicat, D-79110 Freiburg, Germany
[3] Univ Freiburg, Ctr Biol Signalling Studies Bioss, D-7800 Freiburg, Germany
关键词
TOTAL ANALYSIS SYSTEMS; MICROFLUIDICS; MICROFABRICATION; PCR;
D O I
10.1039/b926139g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Self-containing, ready-to-use cartridges are essential for mobile Lab-on-a-Chip (LoaC) systems intended for Point-of-Care (POC) use. Up to now, a common weak point in many LoaC developments is the need to dispense liquid reagents into the test cartridge before or during processing of the assay. To address this issue we have developed an efficient method for fusing liquid reagents into glass ampoules, which are then sealed into a centrifugally operated cartridge. For on-demand reagent release, the ampoules are disrupted through the flexible lid of the cartridge. Upon centrifugation, 98.7 mu L out of 100 mu L (CV = 2.5%) of the pre-stored contents are released into the microfluidic system. No liquid loss is observed for ethanol and H2O stored for 300 days at room temperature. Frozen storage is possible without damage to the ampoules. Applicability of this concept is demonstrated by performing a LoaC integrated DNA extraction after 140 days of reagent pre-storage. DNA yield from 32 mu L of whole blood was up to 199 ng, which is 77% of an off-chip reference extraction. The presented approach allows the improvement of existing LoaC cartridges where pre-storage of liquid reagents was not implemented yet.
引用
收藏
页码:1480 / 1484
页数:5
相关论文
共 41 条
[1]   Lab-on-chip technologies:: making a microfluidic network and coupling it into a complete microsystem -: a review [J].
Abgrall, P. ;
Gue, A-M .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (05) :R15-R49
[2]   Disposable Smart lab on a chip for point-of-care clinical diagnostics [J].
Ahn, CH ;
Choi, JW ;
Beaucage, G ;
Nevin, JH ;
Lee, JB ;
Puntambekar, A ;
Lee, JY .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :154-173
[3]   A miniature integrated device for automated multistep genetic assays [J].
Anderson, Rolfe C. ;
Su, Xing ;
Bogdan, Gregory J. ;
Fenton, Jeffery .
NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
[4]   Microfabrication and microfluidics for tissue engineering: state of the art and future opportunities [J].
Andersson, H ;
van den Berg, A .
LAB ON A CHIP, 2004, 4 (02) :98-103
[5]   Controlled microfluidic interfaces [J].
Atencia, J ;
Beebe, DJ .
NATURE, 2005, 437 (7059) :648-655
[6]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[7]   Hands-free sample preparation platform for nucleic acid analysis [J].
Baier, T. ;
Hansen-Hagge, T. E. ;
Gransee, R. ;
Crombe, A. ;
Schmahl, S. ;
Paulus, C. ;
Drese, K. S. ;
Keegan, H. ;
Martin, C. ;
O'Leary, J. J. ;
Furuberg, L. ;
Solli, L. ;
Gronn, P. ;
Falang, I. M. ;
Karlgard, A. ;
Gulliksen, A. ;
Karlsen, F. .
LAB ON A CHIP, 2009, 9 (23) :3399-3405
[8]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[9]  
2-7
[10]   Chips, money, industry, education and the "killer application'' [J].
Becker, Holger .
LAB ON A CHIP, 2009, 9 (12) :1659-1660