Cardiac Output Monitoring: A Contemporary Assessment and Review

被引:117
作者
Thiele, Robert H. [1 ]
Bartels, Karsten [2 ]
Gan, Tong J. [3 ]
机构
[1] Univ Virginia, Dept Anesthesiol, Charlottesville, VA 22904 USA
[2] Univ Colorado Denver, Dept Anesthesiol, Aurora, CO USA
[3] SUNY Stony Brook, Dept Anesthesiol, Stony Brook, NY 11794 USA
关键词
cardiac output; echocardiography; goal-directed therapy; hemodynamic monitoring; minimally invasive monitoring; pulmonary artery catheter; PULMONARY-ARTERY CATHETER; PULSE-CONTOUR ANALYSIS; WAVE-FORM ANALYSIS; RESPIRATORY-DISTRESS-SYNDROME; CRITICALLY-ILL PATIENTS; BLOOD-PRESSURE; LITHIUM DILUTION; TRANSPULMONARY THERMODILUTION; NONINVASIVE MEASUREMENT; RESPONSE-TIME;
D O I
10.1097/CCM.0000000000000608
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Objective: An increasing number of minimally or noninvasive devices are available to measure cardiac output in the critical care setting. This article reviews the underlying physical principles of these devices in addition to examining both animal and human comparative studies in an effort to allow clinicians to make informed decisions when selecting a device to measure cardiac output. Data Sources: Peer-reviewed manuscripts indexed in PubMed. Study Selection: A systematic search of the PubMed database for articles describing the use of cardiac output monitors yielded 1,526 sources that were included in the analysis. Data Extraction: From all published cardiac output monitoring studies reviewed, the animal model, number of independent measurements, and correlation between techniques was extracted. Data Synthesis: Comparative studies in animals and humans between devices designed for measurement of cardiac output and experimental reference standards indicate thermodilution and Doppler-based techniques to have acceptable accuracy across a wide range of hemodynamic conditions, with bioimpedance techniques being less accurate. Thermodilution devices are marginally more accurate than Doppler-based devices but suffer from slower response time, increased invasiveness, and require stable core temperatures, good operator technique, and a competent tricuspid valve. Doppler-based techniques are less invasive and offer beat-to-beat measurements and excellent trending ability, but are dependent on accurate beam alignment and knowledge of aortic cross-sectional area. Studies of newer devices, such as pulse contour analysis, partial rebreathing, and pulse wave velocity, are far less in number and are primarily based on comparisons with thermodilution-based cardiac output measurements. Studies show widely ranging results. Conclusion: Thermodilution is relatively accurate for cardiac output measurements in both animals and humans when compared to experimental reference standards. Doppler-based techniques appear to have similar accuracy as thermodilution pulmonary artery catheters. Bioimpedance, pulse contour, partial rebreathing, and pulse wave velocity-based devices have not been studied as rigorously; however, the majority of studies included in this analysis point towards decreased accuracy.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 102 条
[1]
DIAMETER AND ELASTICITY OF ASCENDING AORTA DURING INFUSION OF NORADRENALINE [J].
AARS, H .
ACTA PHYSIOLOGICA SCANDINAVICA, 1971, 83 (01) :133-&
[2]
Pulmonary Capillary Blood Flow and Cardiac Output Measurement by Partial Carbon Dioxide Rebreathing in Patients with Acute Respiratory Distress Syndrome Receiving Lung Protective Ventilation [J].
Allardet-Servent, Jerome ;
Forel, Jean-Marie ;
Roch, Antoine ;
Chiche, Laurent ;
Guervilly, Christophe ;
Bouzana, Fouad ;
Vincent, Agnes ;
Gainnier, Marc ;
Loundou, Anderson ;
Papazian, Laurent .
ANESTHESIOLOGY, 2009, 111 (05) :1085-1092
[3]
Continuous cardiac output catheters -: Delay in in vitro response time after controlled flow changes [J].
Aranda, M ;
Mihm, FG ;
Garrett, S ;
Mihm, MN ;
Pearl, RG .
ANESTHESIOLOGY, 1998, 89 (06) :1592-1595
[4]
Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model [J].
Bajorat, J ;
Hofmockel, R ;
Vagts, DA ;
Janda, M ;
Pohl, B ;
Beck, C ;
Noeldge-Schomburg, G .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (01) :23-30
[5]
ERRORS IN THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS CAUSED BY RAPID PULMONARY-ARTERY TEMPERATURE DECREASES AFTER CARDIOPULMONARY BYPASS [J].
BAZARAL, MG ;
PETRE, J ;
NOVOA, R .
ANESTHESIOLOGY, 1992, 77 (01) :31-37
[6]
The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration [J].
Bein, Berthold ;
Meybohm, Patrick ;
Cavus, Erol ;
Renner, Jochen ;
Tonner, Peter H. ;
Steinfath, Markus ;
Scholz, Jens ;
Doerges, Volker .
ANESTHESIA AND ANALGESIA, 2007, 105 (01) :107-113
[7]
Time series analysis of use patterns for common invasive technologies in critically ill patients [J].
Berthiaume, Luc R. ;
Peets, Adam D. ;
Schmidt, Ulrich ;
Shahpori, Reza ;
Doig, Chip J. ;
Boiteau, Paul J. E. ;
Stelfox, Henry Thomas .
JOURNAL OF CRITICAL CARE, 2009, 24 (03) :471.e9-471.e14
[8]
Evaluation of a New Software Version of the FloTrac/Vigileo (Version 3.02) and a Comparison with Previous Data in Cirrhotic Patients Undergoing Liver Transplant Surgery [J].
Biancofiore, Gianni ;
Critchley, Lester A. H. ;
Lee, Anna ;
Yang, Xiao-xing ;
Bindi, Lucia M. ;
Esposito, Massimo ;
Bisa, Massimo ;
Meacci, Luca ;
Mozzo, Roberto ;
Filipponi, Franco .
ANESTHESIA AND ANALGESIA, 2011, 113 (03) :515-522
[9]
Agreed Statistics Measurement Method Comparison [J].
Bland, J. Martin ;
Altman, Douglas G. .
ANESTHESIOLOGY, 2012, 116 (01) :182-185
[10]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310