Sensor for fisetin based on gold nanoparticles in ionic liquid and binuclear nickel complex immobilized in silica

被引:21
作者
Brondani, Daniela [1 ]
Vieira, Iolanda Cruz [1 ]
Piovezan, Clovis [2 ]
Ramos da Silva, Jaqueline Maria [2 ]
Neves, Ademir [2 ]
Dupont, Jairton [3 ]
Scheeren, Carla Weber [3 ]
机构
[1] Univ Fed Santa Catarina, Lab Biosensors, Dept Chem, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Lab Bioinorgan & Crystallog, Dept Chem, BR-88040900 Florianopolis, SC, Brazil
[3] Univ Fed Rio Grande do Sul, Lab Mol Catalysis, Inst Chem, BR-91501970 Porto Alegre, RS, Brazil
关键词
PLANT FLAVONOID FISETIN; CARBON-PASTE ELECTRODE; CELL-CYCLE ARREST; VOLTAMMETRIC DETERMINATION; PHENOLIC-COMPOUNDS; GEL; BIOSENSOR; SURFACE; LACCASE; OXIDATION;
D O I
10.1039/b925533h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold nanoparticles dispersed in an ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (Au-BMI.PF(6)) and a binuclear nickel(II) complex ([Ni(2)(HBPPAMFF)mu-(OAc)(2)(H(2)O)]BPh(4)) immobilized on functionalized silica were successfully applied in the construction of a novel sensor for the determination of fisetin by square-wave voltammetry. Under optimized conditions, the analytical curve showed two linear ranges for fisetin concentrations from 0.28 to 1.39 mM and 2.77 to 19.50 mM with a detection limit of 0.05 mM. This sensor demonstrated suitable stability (ca. 150 days; at least 500 determinations) and good repeatability and reproducibility, with relative standard deviations of 2.91 and 5.11%, respectively. The recovery study of fisetin in apple juice samples gave values from 96.4 to 106.4%. The efficient analytical performance of the proposed sensor can be attributed to the effective immobilization of the Ni(II)Ni(II) complex on silica and the Au-BMI.PF(6) contribution to the electrode response.
引用
收藏
页码:1015 / 1022
页数:8
相关论文
共 47 条
[11]   Development of a new biomimetic sensor based on an FeIIIFeII complex for the determination of phenolic compounds [J].
de Oliveira, Ines Rosane W. Z. ;
Neves, Ademir ;
Vieira, Iolanda Cruz .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) :424-430
[12]   Analytical separation and detection methods for flavonoids [J].
de Rijke, E ;
Out, P ;
Niessen, WMA ;
Ariese, F ;
Gooijer, C ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1112 (1-2) :31-63
[13]   A regenerable ruthenium tetraammine nitrosyl complex immobilized on a modified silica gel surface: Preparation and studies of nitric oxide release and nitrite-to-NO conversion [J].
Doro, Fabio Gorzoni ;
Rodrigues Filho, Ubirajara P. ;
Tfouni, E. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2007, 307 (02) :405-417
[14]   On the solid, liquid and solution structural organization of imidazolium ionic liquids [J].
Dupont, J .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (03) :341-350
[15]   Physico-chemical processes in imidazolium ionic liquids [J].
Dupont, Jairton ;
Suarez, Paulo A. Z. .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2006, 8 (21) :2441-2452
[16]   Determination of red wine flavonoids by HPLC and effect of aging [J].
Fang, Fang ;
Li, Jing-Ming ;
Pan, Qiu-Hong ;
Huang, Wei-Dong .
FOOD CHEMISTRY, 2007, 101 (01) :428-433
[17]   Biosensor for chlorogenic acid based on an ionic liquid containing iridium nanoparticles and polyphenol oxidase [J].
Fernandes, Suellen C. ;
Moccelini, Sally K. ;
Scheeren, Carla W. ;
Migowski, Pedro ;
Dupont, Jairton ;
Heller, Melina ;
Micke, Gustavo A. ;
Vieira, Iolanda C. .
TALANTA, 2009, 79 (02) :222-228
[18]   Biosensor based on laccase immobilized on microspheres of chitosan crosslinked with tripolyphosphate [J].
Fernandes, Suellen Cadorin ;
de Oliveira, Ines Rosane W. Z. ;
Fatibello-Filho, Oralndo ;
Spinelli, Almir ;
Vieira, Iolanda Cruz .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) :202-207
[19]   Electrocatalytic oxidation of phenolic compounds using an electrode modified with Ni(II) porphyrin adsorbed on SiO2/Nb2O5-phosphate synthesized by the sol-gel method [J].
Francisco, Maria Suzana P. ;
Cardoso, William S. ;
Kubota, Lauro T. ;
Gushikem, Yoshitaka .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 602 (01) :29-36
[20]   Biosensor for luteolin based on silver or gold nanoparticles in ionic liquid and laccase immobilized in chitosan modified with cyanuric chloride [J].
Franzoi, Ana Cristina ;
Vieira, Iolanda Cruz ;
Dupont, Jairton ;
Scheeren, Carla Weber ;
de Oliveira, Luciane Franca .
ANALYST, 2009, 134 (11) :2320-2328