Potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT

被引:20
作者
Halliburton, SS
Stillman, AE
Lieber, M
Kasper, JM
Kuzmiak, SA
White, RD
机构
[1] Cleveland Clin Fdn, Div Radiol HB6, Sect Cardiovasc Imaging, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
关键词
D O I
10.2214/ajr.184.2.01840643
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT was evaluated using Agatston, volume, and mass scoring algorithms. SUBJECTS AND METHODS. Fifty-six patients were imaged twice using an identical prospectively ECG-triggered sequential scanning protocol. The Agatston, volume, and mass scores were computed by two observers independently. In addition, a patient's total Agatston score was referenced to an age- and sex-stratified database to determine a percentile ranking. Interscan, interobserver, and intraobserver variability and the resultant impact on patients' risk stratifications were assessed. RESULTS. Significant interscan differences were found for all mean coronary calcium scores (Wilcoxson's signed rank test, p < 0.0001). Although the median percentage of interscan variability was low for all scoring methods, the interquartile range was wide, indicating significant variability in the data. Median scores (lower quartile-upper quartile) for observers I and 2, respectively, were as follows: Agatston, 5% (0-79%) and 6% (0-83%); volume, 12% (051 %) and 12% (0-57%); and mass, 14% (0-57%) and 14% (0-58%). Interobserver and intraobserver differences between mean calcium scores were not significant, and consequently, lower interobserver and intraobserver variabilities (narrow interquartile ranges of 0-5%) were observed for all scores. Despite significant interscan differences in calcium scores, the percentile ranking assigned to the two scans differed in only 13% of patients. Interobserver differences resulted in a change in the percentile ranking in 7-9% of patients, whereas intraobserver differences caused a change in only 5% of patients. CONCLUSION. The accuracy of sequential MDCT for coronary calcium quantification is sufficient in most cases for stratification of patient risk.
引用
收藏
页码:643 / 648
页数:6
相关论文
共 21 条
[11]   Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT [J].
Kopp, AF ;
Ohnesorge, B ;
Becker, C ;
Schröder, S ;
Heuschmid, M ;
Küttner, A ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2002, 225 (01) :113-119
[12]   Reproducibility of two coronary calcium quantification algorithms in patients with different degrees of calcification [J].
Möhlenkamp, S ;
Behrenbeck, TR ;
Pump, H ;
Kriener, P ;
Lange, S ;
Baumgart, D ;
Seibel, RMM ;
Grönemeyer, DHW ;
Erbel, R .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (02) :133-142
[13]   American College of Cardiology/American Heart Association expert consensus document on electron-beam computed tomography for the diagnosis and prognosis of coronary artery disease [J].
O'Rourke, RA ;
Brundage, BH ;
Froelicher, VF ;
Greenland, P ;
Grundy, SM ;
Hachamovitch, R ;
Pohost, GM ;
Shaw, LJ ;
Weintraub, WS ;
Winters, WL ;
Forrester, JS ;
Douglas, PS ;
Faxon, DP ;
Fisher, JD ;
Gregoratos, G ;
Hochman, JS ;
Hutter, AM ;
Kaul, S ;
O'Rourke, RA ;
Weintraub, WS ;
Winters, WL ;
Wolk, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (01) :326-340
[14]   Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT [J].
Ohnesorge, B ;
Flohr, T ;
Fischbach, R ;
Kopp, AF ;
Knez, A ;
Schröder, S ;
Schöpf, UJ ;
Crispin, A ;
Klotz, E ;
Reiser, MF ;
Becker, CR .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1532-1540
[15]   Identification of patients at increased risk of first unheralded acute myocardial infarction by electron-beam computed tomography [J].
Raggi, P ;
Callister, TQ ;
Cooil, B ;
He, ZX ;
Lippolis, NJ ;
Russo, DJ ;
Zelinger, A ;
Mahmarian, JJ .
CIRCULATION, 2000, 101 (08) :850-855
[16]   Electron beam computed tomographic coronary calcium scanning: A review and guidelines for use in asymptomatic persons [J].
Rumberger, JA ;
Brundage, BH ;
Rader, DJ ;
Kondos, G .
MAYO CLINIC PROCEEDINGS, 1999, 74 (03) :243-252
[17]   Age and gender distribution of coronary artery calcium measured by four-slice computed tomography in 2,030 persons with no symptoms of coronary artery disease [J].
Schmermund, A ;
Erbel, R ;
Silber, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (02) :168-+
[18]   Describing data: Statistical and graphical methods [J].
Sonnad, SS .
RADIOLOGY, 2002, 225 (03) :622-628
[19]   Assessment of calcium scoring performance in cardiac computed tomography [J].
Ulzheimer, S ;
Kalender, WA .
EUROPEAN RADIOLOGY, 2003, 13 (03) :484-497
[20]   Coronary artery calcification: Pathophysiology, epidemiology, imaging methods, and clinical implications - A statement for health professionals from the American Heart Association [J].
Wexler, L ;
Brundage, B ;
Crouse, J ;
Detrano, R ;
Fuster, V ;
Maddahi, J ;
Rumberger, J ;
Stanford, W ;
White, R ;
Taubert, K .
CIRCULATION, 1996, 94 (05) :1175-1192