Frequency estimation precision in Doppler optical coherence tomography using the Cramer-Rao lower bound

被引:62
作者
Yazdanfar, S [1 ]
Yang, CH [1 ]
Sarunic, MV [1 ]
Izatt, JA [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
来源
OPTICS EXPRESS | 2005年 / 13卷 / 02期
关键词
D O I
10.1364/OPEX.13.000410
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Doppler optical coherence tomography ( DOCT) is a technique for simultaneous cross-sectional imaging of tissue structure and blood flow. We derive the fundamental uncertainty limits on frequency estimation precision in DOCT using the Cramer-Rao lower bound in the case of additive ( e. g., thermal, shot) noise. Experimental results from a mirror and a scattering phantom are used to verify the theoretical limits. Our results demonstrate that the stochastic nature of frequency noise influences the precision of flow imaging, and that the noise model must be selected judiciously in order to estimate the frequency precision. (C) 2005 Optical Society of America.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 21 条
[1]   Statistics and reduction of speckle in optical coherence tomography [J].
Bashkansky, M ;
Reintjes, J .
OPTICS LETTERS, 2000, 25 (08) :545-547
[2]   Using dynamic low-coherence interferometry to image Brownian motion within highly scattering media [J].
Boas, DA ;
Bizheva, KK ;
Siegel, AM .
OPTICS LETTERS, 1998, 23 (05) :319-321
[3]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[4]  
Goodman J., 2000, Statistical Optics
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   Direct velocity sensing of flow distribution based on low-coherence interferometry [J].
Imai, Y ;
Tanaka, K .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (08) :2007-2012
[7]   In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomograghy [J].
Izatt, JA ;
Kulkami, MD ;
Yazdanfar, S ;
Barton, JK ;
Welch, AJ .
OPTICS LETTERS, 1997, 22 (18) :1439-1441
[8]   Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography [J].
Kulkarni, MD ;
van Leeuwen, TG ;
Yazdanfar, S ;
Izatt, JA .
OPTICS LETTERS, 1998, 23 (13) :1057-1059
[9]   Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography [J].
Leitgeb, RA ;
Schmetterer, L ;
Drexler, W ;
Fercher, AF ;
Zawadzki, RJ ;
Bajraszewski, T .
OPTICS EXPRESS, 2003, 11 (23) :3116-3121
[10]   Quantitative assessment of flow velocity-estimation algorithms for optical Doppler tomography imaging [J].
Piao, DQ ;
Otis, LL ;
Dutta, NK ;
Zhu, Q .
APPLIED OPTICS, 2002, 41 (29) :6118-6127