The monitoring of methane fermentation in sequencing batch bioreactor with flow-through array of miniaturized solid state electrodes

被引:30
作者
Buczkowska, Agnieszka [1 ]
Witkowska, Emilia [1 ]
Gorski, Lukasz [1 ]
Zamojska, Anna [2 ]
Szewczyk, Krzysztof W. [2 ]
Wroblewski, Wojciech [1 ]
Ciosek, Patrycja [1 ]
机构
[1] Warsaw Univ Technol, Fac Chem, PL-00664 Warsaw, Poland
[2] Warsaw Univ Technol, Fac Chem & Proc Engn, PL-00645 Warsaw, Poland
关键词
Electronic tongue; Solid state electrodes; Sensor array; Methane fermentation; Anaerobic digestion; POLYMERIC MEMBRANE ELECTRODES; ANAEROBIC-DIGESTION; SELECTIVE MEMBRANES; TONGUE; RECOGNITION; SYSTEMS; BEVERAGES; MODEL; ADM1;
D O I
10.1016/j.talanta.2010.02.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electronic tongues (ETs) based on potentiometric sensor arrays are often used for foodstuff classification, origin recognition, estimation of complex samples' properties, etc In the last few years they were also applied for various fermentation monitoring, such as Aspergillus niger fermentation, light cheese production, batch Escherichia coli fermentation, as a devices capable of fast, inexpensive, automated and on-line control of the process. In this work a novel application for ET is proposed flow-through array of solid state electrodes was used for the analysis of samples obtained during methane fermentation (anaerobic digestion) of whey in sequencing batch bioreactor, according to their volatile fatty acid (VFA) content and chemical oxygen demand (COD). (C) 2010 Elsevier B.V All rights reserved.
引用
收藏
页码:1387 / 1392
页数:6
相关论文
共 21 条
[1]  
Batstone DJ, 2002, WATER SCI TECHNOL, V45, P65
[2]  
CHANIOTAKIS NA, 1988, ANAL CHEM, V60, P188
[3]   Monitoring of cell cultures with LTCC microelectrode array [J].
Ciosek, P. ;
Zawadzki, K. ;
Lopacinska, J. ;
Skolimowski, M. ;
Bembnowicz, P. ;
Golonka, L. J. ;
Brzozka, Z. ;
Wroblewski, W. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (08) :2029-2038
[4]   Analysis of dialysate fluids with the use of a potentiometric electronic tongue [J].
Ciosek, Patrycja ;
Grabowska, Ilona ;
Brzozka, Zbigniew ;
Wroblewski, Wojciech .
MICROCHIMICA ACTA, 2008, 163 (1-2) :139-145
[5]   Potentiometric electronic tongue based on integrated array of microelectrodes [J].
Ciosek, Patrycja ;
Maminska, Renata ;
Dybko, Artur ;
Wroblewski, Wojciech .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) :8-14
[6]   Sensor arrays for liquid sensing -: electronic tongue systems [J].
Ciosek, Patrycja ;
Wroblewski, Wojciech .
ANALYST, 2007, 132 (10) :963-978
[7]   Performance of selective and partially selective sensors in the recognition of beverages [J].
Ciosek, Patrycja ;
Wroblewski, Wojciech .
TALANTA, 2007, 71 (02) :738-746
[8]   Electronic tongue for flow-through analysis of beverages [J].
Ciosek, Patrycja ;
Brzozka, Zbigniew ;
Wroblewski, Wojciech .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 118 (1-2) :454-460
[9]   The recognition of growth conditions and metabolic type of plants by a potentiometric electronic tongue [J].
Ciosek, Patrycja ;
Pokorska, Berenika ;
Romanowska, Elzbieta ;
Wroblewski, Wojciech .
ELECTROANALYSIS, 2006, 18 (13-14) :1266-1272
[10]   Fermentation monitoring using multisensor systems: feasibility study of the electronic tongue [J].
Esbensen, K ;
Kirsanov, D ;
Legin, A ;
Rudnitskaya, A ;
Mortensen, J ;
Pedersen, J ;
Vognsen, L ;
Makarychev-Mikhailov, S ;
Vlasov, Y .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :391-395