Durability of Antirestenotic Efficacy in Drug-Eluting Stents With and Without Permanent Polymer

被引:144
作者
Byrne, Robert A. [1 ]
Iijima, Raisuke [1 ]
Mehilli, Julinda [1 ]
Pinieck, Susanne [1 ]
Bruskina, Olga [1 ]
Schoemig, Albert [1 ,2 ]
Kastrati, Adnan [1 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum, Munich, Germany
[2] Tech Univ Munich, Med Klin Rechts Isar 1, Munich, Germany
关键词
coronary restenosis; stents/adverse effects; follow-up studies; cell proliferation/drug effects; immunosuppressive agents/therapeutic uses; polymers; 2-year reangiography; BARE-METAL STENTS; INTRAVASCULAR ULTRASOUND ANALYSIS; PORCINE CORONARY MODEL; ANGIOGRAPHIC FOLLOW-UP; CLINICAL END-POINTS; RANDOMIZED-TRIAL; LATE RESTENOSIS; PACLITAXEL; IMPLANTATION; ANGIOPLASTY;
D O I
10.1016/j.jcin.2008.11.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to assess changes in antirestenotic efficacy of drug-eluting stents (DES) by restudying subjects at 2 time points after coronary stenting (6 to 8 months and 2 years) and to compare differences in time courses of late luminal loss (LLL) between 3 different DES platforms in use at our institution. Background DES therapy is associated with low levels of LLL at 6 to 8 months. The temporal course of neointimal formation after this time point remains unclear. Methods This prospective, observational, systematic angiographic follow-up study was conducted at 2 centers in Munich, Germany. Patients underwent stenting with permanent-polymer rapamycineluting stents (RES), polymer-free RES, or permanent-polymer paclitaxel-eluting stents (PES). The primary end point was delayed LLL (the difference in in-stent LLL between 6 to 8 months and 2 years). Results Of 2,588 patients undergoing stenting, 2,030 patients (78.4%) had 6- to 8-month angiographic follow-up and were enrolled in the study. Target lesion revascularization was performed in 259 patients; these patients were not considered for further angiographic analysis. Of 1,771 remaining patients, 1,331 had available 2-year reangiographic data (75.2%). Overall mean (SD) delayed LLL was 0.12 +/- 0.49 mm (0.17 +/- 0.50 mm, 0.01 +/- 0.42 mm, and 0.13 +/- 0.50 mm in permanent-polymer RES, polymer-free RES, and permanent-polymer PES groups, respectively [p < 0.001]). In multivariate analysis, only stent type (in favor of polymer-free RES) predicted delayed LLL. Conclusions Ongoing erosion of luminal caliber beyond 6 to 8 months after the index procedure is observed following DES implantation. Absence of permanent polymer from the DES platform seems to militate against this effect. (J Am Coll Cardiol Intv 2009;2:291-99) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:291 / 299
页数:9
相关论文
共 40 条
[31]   Four-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents [J].
Sousa, JE ;
Costa, MA ;
Abizaid, A ;
Feres, F ;
Seixas, AC ;
Tanajura, LF ;
Mattos, LA ;
Falotico, R ;
Jaeger, J ;
Popma, JJ ;
Serruys, PW ;
Sousa, AGMR .
CIRCULATION, 2005, 111 (18) :2326-2329
[32]   A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents [J].
Spaulding, Christian ;
Daemen, Joost ;
Boersma, Eric ;
Cutlip, Donald E. ;
Serruys, Patrick W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :989-997
[33]   Outcomes associated with drug-eluting and bare-metal stents:: a collaborative network meta-analysis [J].
Stettler, Christoph ;
Wandel, Simon ;
Allemann, Sabin ;
Kastrati, Adnan ;
Morice, Marie Claude ;
Schoemig, Albert ;
Pfisterer, Matthias E. ;
Stone, Gregg W. ;
Leon, Martin B. ;
Suarez de Lezo, Jose ;
Goy, Jean Jacques ;
Park, Seung-Jung ;
Sabate, Manel ;
Suttorp, Maarten J. ;
Kelbaek, Henning ;
Spaulding, Christian ;
Menichelli, Maurizio ;
Vermeersch, Paul ;
Dirksen, Maurits T. ;
Cervinka, Pavel ;
Petronio, Anna Sonia ;
Nordmann, Alain J. ;
Diem, Peter ;
Meier, Bernhard ;
Zwahlen, Marcel ;
Reichenbach, Stephan ;
Trelle, Sven ;
Windecker, Stephan ;
Jueni, Peter .
LANCET, 2007, 370 (9591) :937-948
[34]   Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents [J].
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Ellis, Stephen G. ;
Schofer, Joachim ;
Dawkins, Keith D. ;
Morice, Marie-Claude ;
Colombo, Antonio ;
Schampaert, Erick ;
Grube, Eberhard ;
Kirtane, Ajay J. ;
Cutlip, Donald E. ;
Fahy, Martin ;
Pocock, Stuart J. ;
Mehran, Roxana ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :998-1008
[35]   Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease - A randomized controlled trial [J].
Stone, GW ;
Ellis, SG ;
Cannon, L ;
Mann, JT ;
Greenberg, JD ;
Spriggs, D ;
O'Shaughnessy, CD ;
DeMaio, S ;
Hall, P ;
Popma, JJ ;
Koglin, J ;
Russell, ME .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (10) :1215-1223
[36]   Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation [J].
Takano, Masamichi ;
Ohba, Takayoshi ;
Inami, Shigenobu ;
Seimiya, Koji ;
Sakai, Shunta ;
Mizuno, Kyoichi .
EUROPEAN HEART JOURNAL, 2006, 27 (18) :2189-2195
[37]   Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent should we be cautious? [J].
Virmani, R ;
Guagliumi, G ;
Farb, A ;
Musumeci, G ;
Grieco, N ;
Motta, T ;
Mihalcsik, L ;
Tespili, M ;
Valsecchi, O ;
Kolodgie, FD .
CIRCULATION, 2004, 109 (06) :701-705
[38]   Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans [J].
Virmani, R ;
Liistro, F ;
Stankovic, G ;
Di Mario, C ;
Montorfano, M ;
Farb, A ;
Kolodgie, FD ;
Colombo, A .
CIRCULATION, 2002, 106 (21) :2649-2651
[39]   Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent [J].
Wessely, R ;
Kastrati, A ;
Schömig, A .
ANNALS OF INTERNAL MEDICINE, 2005, 143 (05) :392-394
[40]   Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS):: a randomised non-inferiority trial [J].
Windecker, Stephan ;
Serruys, Patrick W. ;
Wandel, Simon ;
Buszman, Pawel ;
Trznadel, Stanislaw ;
Linke, Axel ;
Lenk, Karsten ;
Ischinger, Thomas ;
Klauss, Volker ;
Eberli, Franz ;
Corti, Roberto ;
Wijns, William ;
Morice, Marie Claude ;
di Mario, Carlo ;
Davies, Simon ;
van Geuns, Robert-Jan ;
Eerdmans, Pedro ;
van Es, Gerrit-Anne ;
Meier, Bernhard ;
Jueni, Peter .
LANCET, 2008, 372 (9644) :1163-1173