Surface Function Actives

被引:13
作者
Duan, Qi [1 ,2 ]
Angelini, Elsa D. [3 ]
Laine, Andrew F. [2 ]
机构
[1] NYU, Sch Med, Ctr Biomed Imaging, New York, NY 10016 USA
[2] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[3] Ecole Natl Super Telecommun Bretagne, LTCI, Dept Image & Signal Proc, CNRS,UMR 5141, Paris, France
关键词
Surface Function Actives; Image segmentation; Deformable model; Real-time segmentation; Variational approach; Interface representation; CONTOUR MODEL; SEGMENTATION; QUANTIFICATION; ULTRASOUND; TRACKING; MR; IMAGES;
D O I
10.1016/j.jvcir.2009.06.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Deformable models have been widely used in image segmentation since the introduction of the snakes. Later the introduction of level set frameworks to solve the energy minimization problem associated with the deformable model overcame some limitations of the parametric active contours with respect to topological changes by embedding surface representations into higher dimensional functions. However, this may also bring in more computational load so that recent advances in spatio-temporal resolutions of 3D/4D imaging raised some challenges for real-time segmentation, especially for interventional imaging. In this context, a novel segmentation framework, Surface Function Actives (SFA), is proposed for real-time segmentation purpose. SFA has great advantages in terms of potential efficiency, based on its dimensionality reduction for the surface representation. Utilizing implicit representations with variational framework also provides flexibility and benefits currently shared by level set frameworks. An application for minimally-invasive intervention is shown to illustrate the potential applications of this framework. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:478 / 490
页数:13
相关论文
共 48 条
[1]   Segmentation of real-time three-dimensional ultrasound for quantification of ventricular function: A clinical study on right and left ventricles [J].
Angelini, ED ;
Homma, S ;
Pearson, G ;
Holmes, JW ;
Laine, AF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (09) :1143-1158
[2]   LV volume quantification via spatiotemporal analysis of real-time 3-D echocardiography [J].
Angelini, ED ;
Laine, AF ;
Takuma, S ;
Holmes, JW ;
Homma, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (06) :457-469
[3]  
ANGELINI ED, 2004, SPIE INT S MED IM 20, P526
[4]  
[Anonymous], 1999, LEVEL SET METHODS FA
[5]   Fully automated endocardial contour detection in time sequences of echocardiograms by three-dimensional Active Appearance Models [J].
Bosch, JG ;
Mitchell, SC ;
Lelieveldt, BPF ;
Nijland, F ;
Kamp, O ;
Sonka, M ;
Reiber, JHC .
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 :452-462
[6]  
Boukerroui D, 1999, LECT NOTES COMPUT SC, V1679, P516
[7]  
Boykov YY, 2001, EIGHTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOL I, PROCEEDINGS, P105, DOI 10.1109/ICCV.2001.937505
[8]   A multiple active contour model for cardiac boundary detection on echocardiographic sequences [J].
Chalana, V ;
Linker, DT ;
Haynor, DR ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) :290-298
[9]   Active contours without edges [J].
Chan, TF ;
Vese, LA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) :266-277
[10]  
Christie G. R., 2002, Computing and Visualization in Science, V4, P227, DOI 10.1007/s00791-002-0079-3