Multi-channel 3-D cell culture device integrated on a silicon chip for anticancer drug sensitivity test

被引:95
作者
Torisawa, Y
Shiku, H
Yasukawa, T
Nishizawa, M
Matsue, T
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Bioengn & Robot, Sendai, Miyagi 9808579, Japan
关键词
biosensor; collagen; cytotoxicity; electrochemistry; polydimethylsiloxane;
D O I
10.1016/j.biomaterials.2004.05.028
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel three-dimensional cell culture system was constructed with an array of cell panels (4 x 5) in a silicon chip. together with multi-channel drug containers. Human breast cancer (MCF-7) cells were embedded in a collagen-gel matrix and entrapped in a pyramidal-shaped silicon hole. Each cell panel can be isolated by a channel composed of a microfluid part and a reservoir. A cell panel was exposed to 200 mm KCN for 2 days to demonstrate that each cell panel could be independently evaluated under various stimulation conditions. Based on the cellular respiration activity, the proliferation behavior was continuously monitored on the silicon-based cell array for 5 days using scanning electrochemical microscopy (SECM). The cells entrapped in the device (3-D culture) proliferated normally, and the proliferation rate was lower than that of cells grown in a monolayer cell culture (2-D culture). The effects of three anticancer drugs measured simultaneously on the cell chip were in good agreement with those obtained by a conventional colorimetric assay. Our results suggest that the silicon-based device for 3D culture is appropriate for a chemosensitivity assay involving multi-chemical stimulation. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2165 / 2172
页数:8
相关论文
共 53 条
[1]   Cell culture: Biology's new dimension [J].
Abbott, A .
NATURE, 2003, 424 (6951) :870-872
[2]  
Bard A. J., 1994, ELECTROANALYTICAL CH, V18
[3]   High-throughput cell analysis using multiplexed array technologies [J].
Beske, OE ;
Goldbard, S .
DRUG DISCOVERY TODAY, 2002, 7 (18) :S131-S135
[4]   Engineering cellular microenvironments to cell-based drug testing improve [J].
Bhadriraju, K ;
Chen, CS .
DRUG DISCOVERY TODAY, 2002, 7 (11) :612-620
[5]   Whole cell biosensors [J].
Bousse, L .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :270-275
[6]   Functional cellular assays with multiparametric silicon sensor chips [J].
Brischwein, M ;
Motrescu, ER ;
Cabala, E ;
Otto, AM ;
Grothe, H ;
Wolf, B .
LAB ON A CHIP, 2003, 3 (04) :234-240
[7]  
Brown E, 1996, CANCER, V77, P1020, DOI 10.1002/(SICI)1097-0142(19960315)77:6<1020::AID-CNCR3>3.0.CO
[8]  
2-L
[9]   Comparison of the tetrazolium salt assay for succinate dehydrogenase with the cytosensor microphysiometer in the assessment of compound toxicities [J].
Cooke, D ;
O'Kennedy, R .
ANALYTICAL BIOCHEMISTRY, 1999, 274 (02) :188-194
[10]  
CUKEIMAN E, 2002, CURR OPIN CELL BIOL, V14, P633