Multi-channel 3-D cell culture device integrated on a silicon chip for anticancer drug sensitivity test

被引:95
作者
Torisawa, Y
Shiku, H
Yasukawa, T
Nishizawa, M
Matsue, T
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Bioengn & Robot, Sendai, Miyagi 9808579, Japan
关键词
biosensor; collagen; cytotoxicity; electrochemistry; polydimethylsiloxane;
D O I
10.1016/j.biomaterials.2004.05.028
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel three-dimensional cell culture system was constructed with an array of cell panels (4 x 5) in a silicon chip. together with multi-channel drug containers. Human breast cancer (MCF-7) cells were embedded in a collagen-gel matrix and entrapped in a pyramidal-shaped silicon hole. Each cell panel can be isolated by a channel composed of a microfluid part and a reservoir. A cell panel was exposed to 200 mm KCN for 2 days to demonstrate that each cell panel could be independently evaluated under various stimulation conditions. Based on the cellular respiration activity, the proliferation behavior was continuously monitored on the silicon-based cell array for 5 days using scanning electrochemical microscopy (SECM). The cells entrapped in the device (3-D culture) proliferated normally, and the proliferation rate was lower than that of cells grown in a monolayer cell culture (2-D culture). The effects of three anticancer drugs measured simultaneously on the cell chip were in good agreement with those obtained by a conventional colorimetric assay. Our results suggest that the silicon-based device for 3D culture is appropriate for a chemosensitivity assay involving multi-chemical stimulation. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2165 / 2172
页数:8
相关论文
共 53 条
[11]   Patterned delivery of immunoglobulins to surfaces using microfluidic networks [J].
Delamarche, E ;
Bernard, A ;
Schmid, H ;
Michel, B ;
Biebuyck, H .
SCIENCE, 1997, 276 (5313) :779-781
[12]   Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures [J].
Ehret, R ;
Baumann, W ;
Brischwein, M ;
Schwinde, A ;
Stegbauer, K ;
Wolf, B .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :29-41
[13]   Microphysiometry: new technology for evaluation of anticancer drug activity in human tumor cells in vitro [J].
Ekelund, S ;
Nygren, P ;
Larsson, R .
ANTI-CANCER DRUGS, 1998, 9 (06) :531-538
[14]   A MORPHOLOGICAL BIOSENSOR FOR MAMMALIAN-CELLS [J].
GIAEVER, I ;
KEESE, CR .
NATURE, 1993, 366 (6455) :591-592
[15]   Cytosensor® Microphysiometer:: technology and recent applications [J].
Hafner, F .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :149-158
[16]   Approach to a multiparametric sensor-chip-based tumor chemosensitivity assay [J].
Henning, T ;
Brischwein, M ;
Baumann, W ;
Ehret, R ;
Freund, I ;
Kammerer, R ;
Lehmann, M ;
Schwinde, A ;
Wolf, B .
ANTI-CANCER DRUGS, 2001, 12 (01) :21-32
[17]   Taking the study of cancer cell survival to a new dimension [J].
Jacks, T ;
Weinberg, RA .
CELL, 2002, 111 (07) :923-925
[18]   Microelectrochemical approach to induce local cell adhesion and growth on substrates [J].
Kaji, H ;
Kanada, M ;
Oyamatsu, D ;
Matsue, T ;
Nishizawa, M .
LANGMUIR, 2004, 20 (01) :16-19
[19]   Pharmacological characterization of micropatterned cardiac myocytes [J].
Kaji, H ;
Takii, Y ;
Nishizawa, M ;
Matsue, T .
BIOMATERIALS, 2003, 24 (23) :4239-4244
[20]   Patterning proteins and cells using soft lithography [J].
Kane, RS ;
Takayama, S ;
Ostuni, E ;
Ingber, DE ;
Whitesides, GM .
BIOMATERIALS, 1999, 20 (23-24) :2363-2376