Voltametric and flow injection determination of oxytetracycline residues in food samples using carbon fiber microelectrodes

被引:12
作者
Agüí, L [1 ]
Guzman, A [1 ]
Pedrero, M [1 ]
Yáñez-Sedeño, P [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
oxytetracycline; carbon fiber microelectrodes; milk; eggs; flow injection;
D O I
10.1002/elan.200390075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A voltammetric method for the determination of the antibiotic oxytetracycline (OTC) in food samples is reported. Carbon fiber microelectrodes (CFMEs), which allow voltammetric measurements to be performed in a small volume (1 mL) of the analyte extract from the samples, are employed. Repeatable electroanalytical responses were obtained with no need of applying cleaning treatments to the CFME. Under the optimized square-wave conditions, a linear calibration plot for OTC was obtained in the 1.0 x 10(-6)-1.0 x 10(-4) mol L-1 range, with a detection limit of 2.9 x 10(-7) mol L-1 (150 ng mL(-1)) OTC. The determination of OTC by a flow-injection method with amperometric detection using a homemade flow cell specially designed to work with CFMEs, was also evaluated using pure acetonitrile as the carrier. The SW voltammetric method was applied to the determination of OTC in spiked milk and eggs samples, at 100 ng mL(-1) and 200 ng g(-1) levels, respectively. The procedure involved the extraction of the analyte in ethyl acetate, evaporation of the solvent and reconstitution of the residue in acetonitrile -5.0 x 10(-4) mol L-1 tetrabutylammonium perchlorate medium. Recoveries of 96+/-8 and 91+/-8% were obtained for milk and eggs, respectively, by applying the standard additions method.
引用
收藏
页码:601 / 607
页数:7
相关论文
共 36 条
[31]   Use of metal complexation in non-aqueous capillary electrophoresis systems for the separation and improved detection of tetracyclines [J].
Tjornelund, J ;
Hansen, SH .
JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) :235-243
[32]   DETERMINATION OF OXYTETRACYCLINE IN THE LIVE FISH FEED ARTEMIA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
TOURAKI, M ;
RIGAS, P ;
PERGANDAS, P ;
KASTRITSIS, C .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 663 (01) :167-171
[33]   TRACE MEASUREMENTS OF TETRACYCLINES USING ADSORPTIVE STRIPPING VOLTAMMETRY [J].
WANG, J ;
PENG, T ;
LIN, MS .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1986, 15 (02) :147-156
[34]   Analysis of tetracyclines in raw urine by column-switching high-performance liquid chromatography and tandem mass spectrometry [J].
Weimann, A ;
Bojesen, G .
JOURNAL OF CHROMATOGRAPHY B, 1999, 721 (01) :47-54
[35]   Analysis of minocycline by high-performance liquid chromatography in tissue and serum [J].
Wrightson, WR ;
Myers, SR ;
Galandiuk, S .
JOURNAL OF CHROMATOGRAPHY B, 1998, 706 (02) :358-361
[36]   Capillary electrophoresis of some tetracycline antibiotics coupled with reductive fast cyclic voltammetric detection [J].
Zhou, JK ;
Gerhardt, GC ;
Baranski, A ;
Cassidy, R .
JOURNAL OF CHROMATOGRAPHY A, 1999, 839 (1-2) :193-201