MR-guided coil embolisation of renal arteries in an animal model

被引:11
作者
Bücker, A
Neuerburg, JM
Adam, G
Glowinski, A
van Vaals, JJ
Günther, RW
机构
[1] Rhein Westfal TH Aachen, Radiol Diagnost Klin, Med Fak, D-52074 Aachen, Germany
[2] Philips Med Syst, Best, Netherlands
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 02期
关键词
intervention; MR-guided; coil embolisation; real-time MR; radial scanning; passive visualisation;
D O I
10.1055/s-2003-37224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test the feasibility of MR-guided coil embolization with passive visualization in an animal model. Materials and Methods: All experiments were performed on a 1.5 T interventional MR-scanner (Gyroscan ACS-NT, Philips, Netherlands). A gradient echo sequence was combined with radial k-space acquisition and sliding window reconstruction technique to calculate the raw data with a specially designed back projector, yielding a frame rate of 20 images per second. The images were directly displayed on LCD-screens next to the MR scanner. A multipurpose catheter with dysprosium markers was placed into the renal arteries of two pigs under MR guidance, and a nitinol coil and platinum coil each were deployed. The position of the coils was verified with magnetic resonance angiography and conventional angiography. Results: MR-guided catheterization of renal arteries with subsequent coil embolization was successfully carried out but the configuration of the coils could not be visualized on the MR images. Conclusion: MR-guided coil embolization of renal arteries is feasible. Exact guidance of coil deployment is not attainable with passive visualization.
引用
收藏
页码:271 / 274
页数:4
相关论文
共 12 条
[1]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[2]   Stent placement under real-time MR control:: First experience in an animal model. [J].
Bücker, A ;
Neuerburg, JM ;
Adam, G ;
Schürmann, K ;
Rasche, V ;
van Vaals, JJ ;
Molgaard-Nielsen, A ;
Günther, RW .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (06) :655-657
[3]   Real-time MR guidance for inferior vena cava filter placement in an animal model [J].
Bücker, A ;
Neuerburg, JM ;
Adam, GB ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Günther, RW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (06) :753-756
[4]  
Konings MK, 2000, J MAGN RESON IMAGING, V12, P79, DOI 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.3.CO
[5]  
2-K
[6]   Guidewire antennas for MR fluoroscopy [J].
Ladd, ME ;
Erhart, P ;
Debatin, JF ;
Hofmann, E ;
Boesiger, P ;
vonSchulthess, GK ;
McKinnon, GC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :891-897
[7]   Instrument visualization in a magnetic resonance imaging environment [J].
Ladd, ME ;
Debatin, JF .
SEMINARS IN INTERVENTIONAL RADIOLOGY, 1999, 16 (01) :13-21
[8]   Interventional radiology - quo vadis? [J].
Lammer, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (03) :271-272
[9]  
Liu CY, 2000, J MAGN RESON IMAGING, V12, P75, DOI 10.1002/1522-2586(200007)12:1<75::AID-JMRI8>3.0.CO
[10]  
2-#