High-resolution echo-planar imaging of the brain: Is it suitable for routine clinical imaging?

被引:4
作者
Ozdoba, C [1 ]
Remonda, L [1 ]
Heid, O [1 ]
Lovblad, KO [1 ]
Schroth, G [1 ]
机构
[1] Univ Bern, Inselspital, Dept Neuroradiol, CH-3010 Bern, Switzerland
关键词
magnetic resonance imaging; echo-planar sequences;
D O I
10.1007/s002340050516
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To assess the value of echo-planar imaging (EPI) for ultrafast routine clinical diagnostic MRI, we compared four different EPI sequences with conventional T-2-weighted spin-echo images on a commercial clinical imager. We examined 25 randomly selected patients who posed different clinical questions. The images were interpreted by two experienced neuroradiologists blinded as to the sequence used. Image quality and diagnostic certainty were evaluated and the main diagnosis established from the EPI study was compared to that obtained from the T-2-weighted images. Finally, EPI-and T-2-based diagnoses were compared with the diagnosis resulting from a complete MRI examination. Apart from one sequence that was generally rated low as regards both diagnostic certainty and image quality, the EPI sequences were comparable to each other, but inferior to the T-2-weighted images. However, two EPI sequences gave better diagnostic results than T-2-weighted images compared to the full MRI examination. Gradient-echo EPI was particularly sensitive to haemorrhagic lesions. All normal cases were correctly identified on EPI studies. Only two pathological cases were missed; both had isolated cranial nerve lesions. The absence of false-positive results and the high sensitivity to ischaemic and mass lesions mean that EPI can be used for ultra-fast screening. However, from these initial studies, EPI seems unsuitable for neuroradiological investigation of patients who may have subtle lesions whose detection requires either special sequences or administration of contrast medium. EPI can nevertheless be used in addition to high-resolution T-1-weighted images and may replace T-2-weighted spin-echo sequences for special indications.
引用
收藏
页码:833 / 840
页数:8
相关论文
共 13 条
[1]   ESTIMATION OF FETAL LUNG-VOLUME USING ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING [J].
BAKER, PN ;
JOHNSON, IR ;
GOWLAND, PA ;
FREEMAN, A ;
ADAMS, V ;
MANSFIELD, P .
OBSTETRICS AND GYNECOLOGY, 1994, 83 (06) :951-954
[2]   MEASUREMENT OF FETAL LIVER, BRAIN AND PLACENTAL VOLUMES WITH ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING [J].
BAKER, PN ;
JOHNSON, IR ;
GOWLAND, PA ;
HYKIN, J ;
ADAMS, V ;
MANSFIELD, P ;
WORTHINGTON, BS .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (01) :35-39
[3]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[4]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[5]   NORMAL HEART - EVALUATION WITH ECHO-PLANAR MR-IMAGING [J].
DAVIS, CP ;
MCKINNON, GC ;
DEBATIN, JF ;
WETTER, D ;
EICHENBERGER, AC ;
DUEWELL, S ;
VONSCHULTHESS, GK .
RADIOLOGY, 1994, 191 (03) :691-696
[6]   ECHO-PLANAR MR-IMAGING [J].
EDELMAN, RR ;
WIELOPOLSKI, P ;
SCHMITT, F .
RADIOLOGY, 1994, 192 (03) :600-612
[7]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[8]  
PEARLMAN JD, 1994, RADIOL CLIN N AM, V32, P593
[9]   ECHOPLANAR MR-IMAGING FOR CHARACTERIZATION OF ADRENAL MASSES IN PATIENTS WITH MALIGNANT NEOPLASMS - PRELIMINARY EVALUATION OF CALCULATED T2 RELAXATION VALUES [J].
SCHWARTZ, LH ;
PANICEK, DM ;
KOUTCHER, JA ;
HEELAN, RT ;
BAINS, MS ;
BURT, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (04) :911-915
[10]   BRAIN-LESIONS IN PATIENTS WITH MULTIPLE-SCLEROSIS - DETECTION WITH ECHO-PLANAR IMAGING [J].
SIEWERT, B ;
PATEL, MR ;
MUELLER, MF ;
GAA, J ;
DARBY, DG ;
POSER, CM ;
WIELOPOLSKI, PA ;
EDELMAN, RR ;
WARACH, S .
RADIOLOGY, 1995, 196 (03) :765-771