Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system

被引:103
作者
Kitamura, K
Shirato, H
Seppenwoolde, Y
Shimizu, T
Kodama, Y
Endo, H
Onimaru, R
Oda, M
Fujita, K
Shimizu, S
Miyasaka, K
机构
[1] Hokkaido Univ, Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Antoni Van Leeuwenhoek Huis, Netherlands Canc Inst, Dept Radiotherapy, Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 56卷 / 01期
关键词
liver tumors; real-time tracking; intrafractional movement;
D O I
10.1016/S0360-3016(03)00082-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the three-dimensional (3D) intrafractional motion of liver tumors during real-time tumor-tracking radiotherapy (RTRT). Methods and Materials: The data of 20 patients with liver tumors were analyzed. Before treatment, a 2-mm gold marker was implanted near the tumor. The RTRT system used fluoroscopy image processor units to determine the 3D position of the implanted marker. A linear accelerator was triggered to irradiate the tumor only when the marker was located within a permitted region. The automatically recorded tumor-motion data were analyzed to determine the amplitude of the tumor motion, curve shape of the tumor motion, treatment efficiency, frequency of movement, and hysteresis. Each of the following clinical factors was evaluated to determine its contribution to the amplitude of movement: tumor position, existence of cirrhosis, surgical history, tumor volume, and distance between the isocenter and the marker. Results: The average amplitude of tumor motion in the 20 patients was 4 +/- 4 mm (range 1-12), 9 +/- 5 mm (range 2-19), and 5 +/- 3 mm (range 2-12) in the left-right, craniocaudal, and anterior-posterior (AP) direction, respectively. The tumor motion of the right lobe was significantly larger than that of the left lobe in the left-right and AP directions (p = 0.01). The tumor motion of the patients with liver cirrhosis was significantly larger than that of the patients without liver cirrhosis in the left-right and AP directions (p < 0.004). The tumor motion of the patients who had received partial hepatectomy was significantly smaller than that of the patients who had no history of any operation on the liver in the left-right and AP directions (p < 0.03). Thus, three of the five clinical factors examined (i.e., tumor position in the liver, cirrhosis, and history of surgery on the liver) significantly affected the tumor motion of the liver in the transaxial direction during stereotactic irradiation. Frequency analysis revealed that for 9 (45%) of the 20 tumors, the cardiac beat caused measurable motion. The 3D trajectory of the tumor showed hysteresis for 4 (20%) of the 20 tumors. The average treatment efficiency of RTRT was 40%. Conclusion: Tumor location, cirrhosis, and history of surgery on the liver all had an impact on the intrafractional tumor motion of the liver in the transaxial direction. This finding should be helpful in determining the smallest possible margin in individual cases of radiotherapy for liver malignancy. (C) 2003 Elsevier Inc.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 30 条
[11]  
*INT COMM RAD UN M, 1999, 50 ICRU MEAS
[12]  
*INT COMM RAD UN M, 1999, 62 ICRU MEAS
[13]  
KIHLSTROM L, 1993, STEREOT FUNCT NEUROS, V61, P45, DOI 10.1159/000100659
[14]   Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions [J].
Kitamura, K ;
Shirato, H ;
Seppenwoolde, Y ;
Onimaru, R ;
Oda, M ;
Fujita, K ;
Shimizu, S ;
Shinohara, N ;
Harabayashi, T ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1117-1123
[15]   Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT) [J].
Kitamura, K ;
Shirato, H ;
Shimizu, S ;
Shinohara, N ;
Harabayashi, T ;
Shimizu, T ;
Kodama, Y ;
Endo, H ;
Onimaru, R ;
Nishioka, S ;
Aoyama, H ;
Tsuchiya, K ;
Miyasaka, K .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (03) :275-281
[16]   Respiration gated radiotherapy treatment: A technical study [J].
Kubo, HD ;
Hill, BC .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :83-91
[17]   CURRENT RADIOSURGERY PRACTICE - RESULTS OF AN ASTRO SURVEY [J].
LARSON, DA ;
BOVA, F ;
EISERT, D ;
KLINE, R ;
LOEFFLER, J ;
LUTZ, W ;
MEHTA, M ;
PALTA, J ;
SCHEWE, K ;
SCHULTZ, C ;
SHAW, E ;
WILSON, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :523-526
[18]   Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy [J].
Seppenwoolde, Y ;
Shirato, H ;
Kitamura, K ;
Shimizu, S ;
van Herk, M ;
Lebesque, JV ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04) :822-834
[19]   Three-dimensional movement of a liver tumor detected by high-speed magnetic resonance imaging [J].
Shimizu, S ;
Shirato, B ;
Xo, B ;
Kagei, K ;
Nishioka, T ;
Hashimoto, S ;
Tsuchiya, K ;
Aoyama, H ;
Miyasaka, K .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :367-370
[20]   Detection of lung tumor movement in real-time tumor-tracking radiotherapy [J].
Shimizu, S ;
Shirato, H ;
Ogura, S ;
Akita-Dosaka, H ;
Kitamura, K ;
Nishioka, T ;
Kagei, K ;
Nishimura, M ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (02) :304-310