The objectives of the present investigation were (1) to describe Doppler echocardiographic findings for mechanical and biologic aortic valves at an early stage after operation and later in a stable phase and (2) to study the changes occurring between these investigations. Patients (n = 213) who received a mechanical (St. Jude Medical, Omnicarbon) or a biologic (Biocor) valve were studied by Doppler echocardiography within the first week (baseline, n = 203) and after 2 years (late, n = 172). The comparison of baseline with late investigation (mean +/- SD) showed an increase in systolic blood pressure (137 +/- 18.5 to 154 +/- 20.6 mm Hg, p = 0.0001, n = 112), reduction of heart rate (85 +/- 15.3 to 74 +/- 12.0 beats/ min, p = 0.0001, n = 141) and increase in stroke volume (59 +/- 20.6 to 77 +/- 19.8 ml, p = 0.0001, n = 132). Prosthetic Doppler echocardiographic findings demonstrated a reduction in blood flow velocity in the left ventricular outflow tract (V-LVOT, 1.10 +/- 0.25 to 0.96 +/- 0.23 m/sec, p = 0.0001, n = 146) reduction in peak velocity (V-max, 2.72 +/- 0.53 to 2.59 +/- 0.54 m/sec, p = 0.02, n = 150), reduction in mean pressure gradient (Delta P-mean, 18.4 +/- 7.2 to 16.3 +/- 7.3 mm Hg, p = 0.004) and an increase in velocity index (V-max/V-LVOT, 2.56 +/- 0.62 to 2.67 +/- 0.60, p = 0.003, n = 144). The standard deviations of difference between baseline and late investigation expressed as percentage of mean were 25% for V-LVOT, 20% for V-max, 44% for Delta P-mean, and 25% for velocity index. In conclusion, this large reference base provides data that should be useful for the clinician evaluating patients with prosthetic valves early after valve replacement as well as at a later stage. When valve dysfunction is suspected a previous investigation for comparison is helpful, and our data describe the changes that normally may be seen between an early baseline and a late investigation.
引用
收藏
页码:466 / 477
页数:12
相关论文
共 26 条
  • [21] NONINVASIVE ESTIMATION OF VALVE AREA IN PATIENTS WITH AORTIC-STENOSIS BY DOPPLER ULTRASOUND AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    SKJAERPE, T
    HEGRENAES, L
    HATLE, L
    [J]. CIRCULATION, 1985, 72 (04) : 810 - 818
  • [22] PRESSURE RECOVERY IN BILEAFLET HEART-VALVE PROSTHESES - LOCALIZED HIGH VELOCITIES AND GRADIENTS IN CENTRAL AND SIDE ORIFICES WITH IMPLICATIONS FOR DOPPLER-CATHETER GRADIENT RELATION IN AORTIC AND MITRAL POSITION
    VANDERVOORT, PM
    GREENBERG, NL
    PU, M
    POWELL, KA
    COSGROVE, DM
    THOMAS, JD
    [J]. CIRCULATION, 1995, 92 (12) : 3464 - 3472
  • [23] CINERADIOGRAPHY FOR DETERMINATION OF NORMAL AND ABNORMAL FUNCTION IN MECHANICAL HEART-VALVES
    VOGEL, W
    STOLL, HP
    BAY, W
    FROHLIG, G
    SCHIEFFER, H
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (02) : 225 - 232
  • [24] Wang Z, 1995, J Heart Valve Dis, V4, P591
  • [25] VALIDITY OF AN EARLY POSTOPERATIVE BASE-LINE DOPPLER RECORDING AFTER AORTIC-VALVE REPLACEMENT
    WISETH, R
    HEGRENAES, L
    ROSSVOLL, O
    SKJAERPE, T
    HATLE, L
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (09) : 869 - 872
  • [26] YOGANATHAN AP, 1988, J THORAC CARDIOV SUR, V95, P929