In vitro performance testing of three small volume-holding chambers under conditions that correspond with use by infants and small children

被引:28
作者
Mitchell, JP [1 ]
Nagel, MW [1 ]
机构
[1] Trudell Med Int, Med Aerosol Lab, Trudell Med Grp, London, ON N5Z 3M5, Canada
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 1997年 / 10卷 / 04期
关键词
pMDI holding chamber; pediatric; low flow rates;
D O I
10.1089/jam.1997.10.341
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The in vitro behavior of three types of small volume-holding chambers intended for use by infants and small children (child AeroChamber(R), Vent-170 and Space Chamber(TM)) has been compared with two pMDI-delivered aerosol formulations (salbutamol: 100 mu g unit dose and beclomethasone di-propionate (BDP): 50 mu g unit dose) widely prescribed for this age group of patients. All devices were evaluated using a pediatric breathing simulator that created respiratory conditions likely to be encountered with infants and small children. The filter that collected aerosol delivered from the holding chamber on test was located at approximately the position that the patient's lips would be in the mask, by means of an annular support plate glued into the mask itself. At the lowest tidal volume (50 mi), no salbutamol or BDP was delivered by either the Vent-170 or Space Chamber(TM), whereas the unit doses from the child AeroChamber(R) were 39.7 +/- 1.6 mu g and 11.8 +/- 1.2 mu g, respectively. The Vent-170 and Space Chamber(TM) delivered measurable doses of both drugs when the tidal volume was increased to 100 mi and again to 200 mi, however, the corresponding doses available from the AeroChamber(R) were always significantly greater. These findings emphasize the importance of designing in vitro tests that mimic use by the patient group for which the device is intended. In vitro measurements made at constant high flow rates in excess of 20 l/min do not reveal these differences in performance that are clinically significant, and may lead the physician to prescribe a device that under certain conditions may not deliver any drug to infants or small children.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 8 条
[1]   THE OPTIMUM SIZE AND SHAPE OF SPACER DEVICES FOR INHALATIONAL THERAPY [J].
BARRY, PW ;
OCALLAGHAN, C .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 (03) :303-305
[2]  
BARRY PW, 1995, COMMUNICATION
[3]   DESIGN AND CHARACTERISTICS OF A PORTABLE BREATH ACTUATED, PARTICLE-SIZE SELECTIVE MEDICAL AEROSOL INHALER [J].
CORR, D ;
DOLOVICH, M ;
MCCORMACK, D ;
RUFFIN, R ;
OBMINSKI, G ;
NEWHOUSE, M .
JOURNAL OF AEROSOL SCIENCE, 1982, 13 (01) :1-7
[4]   The effect of handling techniques on electrostatic charge on spacer devices: A correlation with in vitro particle size analysis [J].
Dewsbury, NJ ;
Kenyon, CJ ;
Newman, SP .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 137 (02) :261-264
[5]   Particle size measurements for the Space-Chamber metered dose inhaler holding chamber compared with aerochamber and metered dose inhaler alone [J].
Finlay, WH ;
Zuberbuhler, P ;
Mandl, M .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1997, 10 (03) :213-219
[6]   IMPROVEMENT IN SODIUM CROMOGLYCATE DELIVERY FROM A SPACER DEVICE BY USE OF AN ANTISTATIC LINING, IMMEDIATE INHALATION, AND AVOIDING MULTIPLE ACTUATIONS OF DRUG [J].
OCALLAGHAN, C ;
LYNCH, J ;
CANT, M ;
ROBERTSON, C .
THORAX, 1993, 48 (06) :603-606
[7]  
RAU JL, 1994, RESP CARE PHARM, P33
[8]   Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants [J].
Wildhaber, JH ;
Devadason, SG ;
Eber, E ;
Hayden, MJ ;
Everard, ML ;
Summers, QA ;
LeSouef, PN .
THORAX, 1996, 51 (10) :985-988