Combination of EEG and ECG for improved automatic neonatal seizure detection

被引:85
作者
Greene, Barry R. [1 ]
Boylan, Geraldine B.
Reilly, Richard B.
de Chazal, Philip
Connolly, Sean
机构
[1] Univ Coll Dublin, Sch Elect Elect & Mech Engn, Dublin 2, Ireland
[2] Natl Univ Ireland Univ Coll Cork, Dept Paediat & Child Hlth, Cork, Ireland
[3] St Vincent Hosp, Cognit Neurophysiol Lab, Dublin, Ireland
[4] St Vincent Univ Hosp, Dept Clin Neurophysiol, Dublin, Ireland
关键词
neonatal seizure detection; EEG; ECG; EKG;
D O I
10.1016/j.clinph.2007.02.015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Neonatal seizures are the most common central nervous system disorder in newborn infants. A system that could automatically detect the presence of seizures in neonates would be a significant advance facilitating timely medical intervention. Methods: A novel method is proposed for the robust detection of neonatal seizures through the combination of simultaneously-recorded electroencephalogram (EEG) and electrocardiogram (ECG). A patient-specific and a patient-independent system are considered, employing statistical classifier models. Results: Results for the signals combined are compared to results for each signal individually. For the patient-specific system, 617 of 633 (97.52%) expert-labelled seizures were correctly detected with a false detection rate of 13.18%. For the patient-independent system, 516 of 633 (81.44%) expert-labelled seizures were correctly detected with a false detection rate of 28.57%. Conclusions: A novel algorithm for neonatal seizure detection is proposed. The combination of an ECG-based classifier system with a novel multi-channel EEG-based classifier system has led to improved seizure detection performance. The algorithm was evaluated using a large data-set containing ECG and multi-channel EEG of realistic duration and quality. Significance: Analysis of simultaneously-recorded EEG and ECG represents a new approach in seizure detection research and the detection performance of the proposed system is a significant improvement on previous reported results for automated neonatal seizure detection. (C) 2007 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1348 / 1359
页数:12
相关论文
共 27 条
[21]   Non-expert use of the cerebral function monitor for neonatal seizure detection [J].
Rennie, JM ;
Chorley, G ;
Boylan, GB ;
Pressler, R ;
Nguyen, Y ;
Hooper, R .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2004, 89 (01) :F37-F40
[22]  
SCHER MS, 1993, PEDIATRICS, V91, P128
[23]   ICTAL AND INTERICTAL ELECTROGRAPHIC SEIZURE DURATIONS IN PRETERM AND TERM NEONATES [J].
SCHER, MS ;
HAMID, MY ;
STEPPE, DA ;
BEGGARLY, ME ;
PAINTER, MJ .
EPILEPSIA, 1993, 34 (02) :284-288
[24]  
Teich M C, 2000, NONLINEAR BIOMEDICAL, VII
[25]   Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates [J].
Toet, MC ;
van der Meij, W ;
de Vries, LS ;
Uiterwaal, CSPM ;
van Huffelen, KC .
PEDIATRICS, 2002, 109 (05) :772-779
[26]  
Volpe J, 2001, NEUROLOGY NEWBORN
[27]  
ZWEIG MH, 1993, CLIN CHEM, V39, P561