Conductance catheter-based assessment of arterial input impedance, arterial function, and ventricular-vascular interaction in mice

被引:44
作者
Segers, P
Georgakopoulos, D
Afanasyeva, M
Champion, HC
Judge, DP
Millar, HD
Verdonck, P
Kass, DA
Stergiopulos, N
Westerhof, N
机构
[1] Univ Ghent, Hydraul Lab, Cardiovasc Mech & Biofluid Dynam Res Unit, B-9000 Ghent, Belgium
[2] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[3] Johns Hopkins Univ, Sch Med, Dept Med, Baltimore, MD USA
[4] Johns Hopkins Univ, Sch Med, Dept Pathol, Baltimore, MD USA
[5] Millar Instruments, Houston, TX USA
[6] Swiss Fed Inst Technol, Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, Lausanne, Switzerland
[7] Vrije Univ Amsterdam, Ctr Med, ICaR VU, Lab Physiol, Amsterdam, Netherlands
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2005年 / 288卷 / 03期
关键词
hemodynamics; augmentation index; windkessel; arterial stiffness; compliance; ventriculovascular coupling;
D O I
10.1152/ajpheart.00414.2004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Global assessment of both cardiac and arterial function is important for a meaningful interpretation of pathophysiological changes in animal models of cardiovascular disease. We simultaneously acquired left ventricular ( LV) and aortic pressure and LV volume ( V-LV) in 17 open-chest anesthetized mice ( 26.7 +/- 3.2g) during steady-state ( BL) and caval vein occlusion ( VCO) using a 1.4-Fr dual-pressure conductance catheter and in a subgroup of eight animals during aortic occlusion ( AOO). Aortic flow was obtained from numerical differentiation of V-LV. AOO increased input impedance ( Z(in)) for the first two harmonics, increased characteristic impedance ( 0.025 +/- 0.007 to 0.040 +/- 0.011 mmHg (.) mul(-1) (.) s, P < 0.05), and shifted the minimum in Zin from the third to the sixth harmonic. For all conditions, the Zin could be well represented by a four-element windkessel model. The augmentation index increased from 116.7 +/- 7.8% to 145.9 +/- 19.5% ( P < 0.01) as well as estimated pulse-wave velocity ( 3.50 +/- 0.94 to 5.95 +/- 1.62 m/s, P < 0.05) and arterial elastance ( Ea, 4.46 +/- 1.62 to 6.02 +/- 1.43 mmHg/mul, P < 0.01). AOO altered the maximal slope ( E-max, 3.23 +/- 1.02 to 5.53 +/- 1.53 mmHg/mul, P < 0.05) and intercept ( - 19.9 +/- 8.6 to 1.62 +/- 13.51 mul, P < 0.01) of the end-systolic pressure-volume relation but not E-a/E-max ( 1.44 +/- 0.43 to 1.21 +/- 0.37, not significant). We conclude that simultaneous acquisition of Z(in) and arterial function parameters in the mouse, based solely on conductance catheter measurements, is feasible. We obtained an anticipated response of Z(in) and arterial function parameters following VCO and AOO, demonstrating the sensitivity of the measuring technique to induced physiological alterations in murine hemodynamics.
引用
收藏
页码:H1157 / H1164
页数:8
相关论文
共 39 条
[21]   Enhancement of contractility with sustained afterload in the intact murine heart - Blunting of length-dependent activation [J].
Reyes, M ;
Freeman, GL ;
Escobedo, D ;
Lee, SK ;
Steinhelper, ME ;
Feldman, MD .
CIRCULATION, 2003, 107 (23) :2962-2968
[22]   ESPVR of in situ rat left ventricle shows contractility-dependent curvilinearity [J].
Sato, T ;
Shishido, T ;
Kawada, T ;
Miyano, H ;
Miyashita, H ;
Inagaki, M ;
Sugimachi, M ;
Sunagawa, K .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (05) :H1429-H1434
[23]   Pulse pressure method and the area method for the estimation of total arterial compliance in dogs: Sensitivity to wave reflection intensity [J].
Segers, P ;
Verdonck, P ;
Deryck, Y ;
Brimioulle, S ;
Naeije, R ;
Carlier, S ;
Stergiopulos, N .
ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (04) :480-485
[24]   Quantification of the contribution of cardiac and arterial remodeling to hypertension [J].
Segers, P ;
Stergiopulos, N ;
Westerhof, N .
HYPERTENSION, 2000, 36 (05) :760-765
[25]   EVALUATION OF METHODS FOR ESTIMATION OF TOTAL ARTERIAL COMPLIANCE [J].
STERGIOPULOS, N ;
MEISTER, JJ ;
WESTERHOF, N .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (04) :H1540-H1548
[26]  
Stergiopulos N, 1999, PATHOL BIOL, V47, P641
[27]  
Stergiopulos N, 1999, AM J PHYSIOL-HEART C, V276, pH81
[28]   SIMPLE AND ACCURATE WAY FOR ESTIMATING TOTAL AND SEGMENTAL ARTERIAL COMPLIANCE - THE PULSE PRESSURE METHOD [J].
STERGIOPULOS, N ;
MEISTER, JJ ;
WESTERHOF, N .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (04) :392-397
[29]   VENTRICULAR SYSTOLIC PRESSURE-VOLUME AREA AS PREDICTOR OF CARDIAC OXYGEN-CONSUMPTION [J].
SUGA, H ;
HAYASHI, T ;
SHIRAHATA, M .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 240 (01) :H39-H44
[30]   INSTANTANEOUS PRESSURE-VOLUME RELATIONSHIPS AND THEIR RATIO IN EXCISED, SUPPORTED CANINE LEFT-VENTRICLE [J].
SUGA, H ;
SAGAWA, K .
CIRCULATION RESEARCH, 1974, 35 (01) :117-134