Magneto-motive detection of tissue-based macrophages by differential phase optical coherence tomography

被引:34
作者
Oh, Junghwan
Feldman, Marc D.
Kim, Jihoon
Kang, Hyun Wook
Sanghi, Pramod
Milner, Thomas E.
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
[2] Univ Texas, Dept Biomed Engn, Austin, TX 78712 USA
[3] Univ Texas, Hlth Sci Ctr, Div Cardiol, San Antonio, TX 78284 USA
关键词
differential phase optical coherence tomography (DP-OCT); superparamagnetic iron oxide nanoparticles (SPIO); macrophages; magnetic flux density;
D O I
10.1002/lsm.20473
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: A novel method to detect tissue-based macrophages using a combination of superparamagnetic iron oxide (SPIO) nanoparticles and differential phase optical coherence tomography (DP-OCT) with an external oscillating magnetic field is reported. Study Design/Material and Methods: Magnetic force acting on iron-laden tissue-based macrophages was varied by applying a sinusoidal current to a solenoid containing a conical iron core that substantially focused and increased magnetic flux density. Results: Nanoparticle motion was detected with DP-OCT, which can detect tissue movement with nanometer resolution. Frequency response of iron-laden tissue movement was twice the modulation frequency since the magnetic force is proportional to the product of magnetic flux density and gradient. Conclusions: Results of our experiments indicate that DP-OCT can be used to identify tissue-based macrophage when excited by an external focused oscillating magnetic field.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 26 条
[1]  
Akkin T, 2003, LASER SURG MED, P4
[2]   Detection of neural activity using phase-sensitive optical low-coherence reflectometry [J].
Akkin, T ;
Davé, DP ;
Milner, TE ;
Rylander, HG .
OPTICS EXPRESS, 2004, 12 (11) :2377-2386
[3]   Optical low-coherence reflectometer for differential phase measurement [J].
Davé, DP ;
Milner, TE .
OPTICS LETTERS, 2000, 25 (04) :227-229
[4]   Noninvasive detection of clinically occult lymph-node metastases in prostate cancer [J].
Harisinghani, MG ;
Barentsz, J ;
Hahn, PF ;
Deserno, WM ;
Tabatabaei, S ;
van de Kaa, CH ;
de la Rosette, J ;
Weissleder, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (25) :2491-U5
[5]   Effect of superparamagnetic iron oxide on bone marrow [J].
Hundt, W ;
Petsch, R ;
Helmberger, T ;
Reiser, M .
EUROPEAN RADIOLOGY, 2000, 10 (09) :1495-1500
[6]   Spectral-domain optical coherence phase microscopy for quantitative phase-contrast imaging [J].
Joo, C ;
Akkin, T ;
Cense, B ;
Park, BH ;
de Boer, JE .
OPTICS LETTERS, 2005, 30 (16) :2131-2133
[7]   High-efficiency intracellular magnetic labeling with novel superparamagnetic-tat peptide conjugates [J].
Josephson, L ;
Tung, CH ;
Moore, A ;
Weissleder, R .
BIOCONJUGATE CHEMISTRY, 1999, 10 (02) :186-191
[8]   Hemoglobin contrast in magnetomotive optical Doppler tomography [J].
Kim, J ;
Oh, J ;
Milner, TE ;
Nelson, JS .
OPTICS LETTERS, 2006, 31 (06) :778-780
[9]   Monitoring refractive index variations in turbid media using phase-sensitive frequency-domain OCT [J].
Larin, KV ;
Esenaliev, RO ;
Kim, E ;
Oh, S ;
Motamedi, M ;
Milner, TE .
Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 :422-425
[10]   Superparamagnetic iron oxide-based method for quantifying recruitment of monocytes to mouse atherosclerotic lesions in vivo -: Enhancement by tissue necrosis factor-α, interleukin-1β, and interferon-γ [J].
Litovsky, S ;
Madjid, M ;
Zarrabi, A ;
Casscells, SW ;
Willerson, JT ;
Naghavi, M .
CIRCULATION, 2003, 107 (11) :1545-1549