Stent fracture has been observed in noncoronary vessels, especially in the superficial femoral and popliteal arteries and with bare metal stents in saphenous vein grafts of coronary arteries. Since the introduction of drug-eluting stents, stent fractures have also been reported in small studies and case reports. We reviewed these publications to assess what is known regarding the incidence, contributing factors, and clinical implications of drug-eluting stent fracture in coronary arteries. The reported rate of drug-eluting stent fracture in coronary arteries ranges from 1 to 8%, although much of the available literature is derived from single-center studies that are heterogeneous in their study methods. A higher risk of stent fracture may be associated with the right coronary artery location, excessive tortuosity or angulation of the vessel, overlapping stents, and longer stents. The closed-cell design of the Cypher stent has been associated with increased rigidity that may increase the risk of stent fracture, although these studies did not assess the overall outcomes between the Cypher and Taxus stents in a head-to-head comparison. Stent fracture has been shown by most studies to be associated with a statistically increased incidence of focal in-stent restenosis, and some have shown an increased risk of target lesion revascularization. Other complications observed with stent fracture include stent thrombosis, coronary aneurysms, myocardial infarction, and sudden death. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 45 条
[31]   The incidence of arterial stent fractures with exclusion of coronary, aortic, and non-arterial settings [J].
Rits, J. ;
van Herwaarden, J. A. ;
Jahrome, A. K. ;
Krievins, D. ;
Moll, F. L. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 36 (03) :339-345
[33]   Prevalence and clinical impact of stent fractures after femoropopliteal stenting [J].
Scheinert, D ;
Scheinert, S ;
Sax, J ;
Piorkowski, C ;
Bräunlich, S ;
Ulrich, M ;
Biamino, G ;
Schmidt, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (02) :312-315
[34]   Impressive sirolimus-eluting stent fracture immediately after stent implantation: A case report [J].
Serikawa, Takeshi ;
Kawasaki, Tomohiro ;
Koga, Hisashi .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 134 (03) :E113-E116
[35]   Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis? [J].
Shaikh, Fareed ;
Maddikunta, Rajesh ;
Djelmami-Hani, Mohamed ;
Solis, Joaquin ;
Allaqaband, Suhail ;
Bajwa, Tanvir .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (05) :614-618
[36]  
Shite Junya, 2006, Eur Heart J, V27, P1389
[37]   Stent fracture and restenosis in the drug-eluting stent era [J].
Sianos, G ;
Hofma, S ;
Ligthart, JMR ;
Saia, F ;
Hoye, A ;
Lemos, PA ;
Serruys, PW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (01) :111-116
[38]   A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease [J].
Stone, GW ;
Ellis, SG ;
Cox, DA ;
Hermiller, J ;
O'Shaughnessy, C ;
Mann, JT ;
Turco, M ;
Caputo, R ;
Bergin, P ;
Greenberg, J ;
Popma, JJ ;
Russell, ME .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (03) :221-231
[39]   Stent strut fracture-induced restenosis in a bifurcation lesion treated with the crush stenting technique [J].
Surmely, Jean-Francois ;
Kinoshita, Yoshihisa ;
Dash, Debabrata ;
Matsubara, Tetsuo ;
Terashima, Mitsuyasu ;
Ehara, Mariko ;
Ito, Tatsuya ;
Nasu, Kenya ;
Takeda, Yoshihiro ;
Tanaka, Nobuyoshi ;
Suzuki, Takahiko ;
Katoh, Osamu .
CIRCULATION JOURNAL, 2006, 70 (07) :936-938
[40]   Stent fracture following stenting of a myocardial bridge: Report of two cases [J].
Tandar, Anwar ;
Whisenant, Brian K. ;
Michaels, Andrew D. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (02) :191-196