Latex-coated polymeric monolithic ion-exchange stationary phases. 1. Anion-exchange capillary electrochromatography and in-line sample preconcentration in capillary electrophoresis

被引:113
作者
Hutchinson, JP
Zakaria, P
Bowiet, AR
Macka, M
Avdalovic, N
Haddad, PR
机构
[1] Univ Tasmania, Fac Sci Engn & Technol, ACROSS, Hobart, Tas 7001, Australia
[2] Univ Tasmania, ACE CRC, Hobart, Tas 7001, Australia
[3] Dionex Chem Corp, Sunnyvale, CA 94088 USA
关键词
D O I
10.1021/ac048748d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sulfortated methacrylate monolithic polymer has been synthesized inside fused-silica capillaries of diameters 50-533-mum i.d. and coated with 65-nm-diameter fully functionalized quaternary ammonium latex particles (AS18, Dionex Corp.) to form an anion-exchange stationary phase. This stationary phase was used for ion-exchange capillary electrochromatography of inorganic anions in a 75-mum-i.d. capillary with Tris/perchlorate electrolyte and direct UV detection at 195 nm. Seven inorganic anions (bromide, nitrate, iodide, iodate, bromate, thiocyanate, chromate) could be separated over a period of 90 s, and the elution order indicated that both ion exchange and electrophoresis contributed to the separation mechanism. Separation efficiencies of up to 1.66 x 10(5) plates m(-1) were achieved, and the monoliths were stable under pressures of up to 62 MPa. Another latex-coated monolith in a 250-mum-i.d. capillary was used for in-line preconcentration by coupling it to a separation capillary in which the EOF had been reversed using a coating of either a cationic polymer or cationic latex particles. Several capillary volumes of sample were loaded onto the preconcentration monolith, and the analytes (inorganic anions) were then eluted from the monolith with a transient isotachophoretic gradient before being separated by electrophoresis in the separation capillary. Linear calibration curves were obtained for aqueous mixtures of bromide, nitrite, nitrate, and iodide. Recoveries of all analytes except iodide were reduced significantly when the sample matrix contained high levels of chloride. The preconcentration method was applied to the determination of iodide in open ocean water and provided a limit of detection of 75 pM (9.5 ng/L) calculated at a signal-to-noise ratio of 3. The relative standard deviation for migration time and peak area for iodide were 1.1 and 2.7%, respectively (n = 6). Iodide was eluted as an efficient peak. yielding a separation efficiency of 5.13 x 10(7) plates m(-1). This focusing was reproducible for repeated analyses of seawater.
引用
收藏
页码:407 / 416
页数:10
相关论文
共 64 条
[1]   Silica-based monoliths for capillary electrochromatography: Methods of fabrication and their applications in analytical separations [J].
Allen, D ;
El Rassi, Z .
ELECTROPHORESIS, 2003, 24 (22-23) :3962-3976
[2]   On-line preconcentration in capillary electrophoresis using monolithic methacrylate polymers [J].
Baryla, NE ;
Toltl, NP .
ANALYST, 2003, 128 (08) :1009-1012
[3]   Real-time monitoring of picomolar concentrations of iron(II) in marine waters using automated flow injection-chemiluminescence instrumentation [J].
Bowie, AR ;
Achterberg, EP ;
Sedwick, PN ;
Ussher, S ;
Worsfold, PJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (21) :4600-4607
[4]  
Boyce MC, 2000, ELECTROPHORESIS, V21, P3073, DOI 10.1002/1522-2683(20000901)21:15<3073::AID-ELPS3073>3.0.CO
[5]  
2-H
[6]   Open-tubular ion-exchange capillary electrochromatography of inorganic anions [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYST, 2000, 125 (07) :1235-1241
[7]   Towards a microchip-based chromatographic platform. Part 2: Sol-gel phases modified with polyelectrolyte multilayers for capillary electrochromatography [J].
Breadmore, MC ;
Shrinivasan, S ;
Karlinsey, J ;
Ferrance, JP ;
Norris, PM ;
Landers, JP .
ELECTROPHORESIS, 2003, 24 (7-8) :1261-1270
[8]  
Breadmore MC, 2002, ELECTROPHORESIS, V23, P3487, DOI 10.1002/1522-2683(200210)23:20<3487::AID-ELPS3487>3.0.CO
[9]  
2-5
[10]   On-column ion-exchange preconcentration of inorganic anions in open tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 3. Implementation and method development [J].
Breadmore, MC ;
Palmer, AS ;
Curran, M ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2112-2118