Multiplanar and three-dimensional imaging of the thorax

被引:17
作者
Ravenel, JG
McAdams, HP
机构
[1] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
D O I
10.1016/S0033-8389(03)00032-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Progressive improvements in helical CT scanners over the past few years have greatly revolutionized the performance of thoracic CT studies. As multi-detector capabilities have increased from dual-slice to 16-slice imaging, thinner sections can be acquired faster and with greater Z-axis coverage. Multidimensional imaging with near isotropic voxels and fewer artifacts is possible with these new scanners. Computer hardware has similarly improved such that a three-dimensional image that once took an hour to create can be performed at the touch of a button. This allows for more precise vascular imaging and can provide surgeons exquisite anatomic data for surgical planning. The possibility of noninvasive coronary artery imaging with CT is closer to reality than ever. Within the lung, the tracheobronchial tree can be mapped, pulmonary nodules can be detected and categorized more readily, and lung volumes can be measured precisely. The demand for such images will likely increase in the foreseeable future. This article discusses practical clinical applications of multidimensional imaging within the thorax.
引用
收藏
页码:475 / +
页数:16
相关论文
共 80 条
[31]   Thoracic aortic aneurysm and aortic dissection: New endoscopic mode for three-dimensional CT display of aorta [J].
Kimura, F ;
Shen, Y ;
Date, S ;
Azemoto, S ;
Mochizuki, T .
RADIOLOGY, 1996, 198 (02) :573-578
[32]   CT angiography with volume rendering for quantifying vascular stenoses: In vitro validation of accuracy [J].
Kuszyk, BS ;
Heath, DG ;
Johnson, PT ;
Eng, J ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) :449-455
[33]   Evaluation of tracheobronchial disease with helical CT with multiplanar and three-dimensional reconstruction correlation with bronchoscopy [J].
Lee, KS ;
Yoon, JH ;
Kim, TK ;
Kim, JS ;
Chung, MP ;
Kwon, OJ .
RADIOGRAPHICS, 1997, 17 (03) :555-567
[34]   Pulmonary vein morphology in patients with paroxysmal atrial fibrillation initiated by ectopic beats originating from the pulmonary veins - Implications for catheter ablation [J].
Lin, WS ;
Prakash, VS ;
Tai, CT ;
Hsieh, MH ;
Tsai, CF ;
Yu, WC ;
Lin, YK ;
Ding, YA ;
Chang, MS ;
Chen, SA .
CIRCULATION, 2000, 101 (11) :1274-1281
[35]   Spiral CT with multiplanar and three-dimensional reconstructions accurately predicts tracheobronchial pathology [J].
LoCicero, J ;
Costello, P ;
Campos, CT ;
Francalancia, N ;
Dushay, KM ;
Silvestri, RC ;
Zibrak, JD .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :811-817
[36]   Clinical outcomes of patients after a negative spiral CT pulmonary arteriogram in the evaluation of acute pulmonary embolism [J].
Lomis, NNT ;
Yoon, HC ;
Moran, AG ;
Miller, FJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (06) :707-712
[37]   Original report - Dose and pitch relationship for a particular multislice CT scanner [J].
Mahesh, M ;
Scatarige, JC ;
Cooper, J ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1273-1275
[38]   Non-invasive imaging of the great vessels of the chest [J].
Marchal, G ;
Bogaert, J .
EUROPEAN RADIOLOGY, 1998, 8 (07) :1099-1105
[39]   Virtual bronchoscopy for directing transbronchial needle aspiration of hilar and mediastinal lymph nodes: A pilot study [J].
McAdams, HP ;
Goodman, PC ;
Kussin, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1361-1364
[40]   Bronchial anastomotic complications in lung transplant recipients: Virtual bronchoscopy for noninvasive assessment [J].
McAdams, HP ;
Palmer, SM ;
Erasmus, JJ ;
Patz, EF ;
Connolly, JE ;
Goodman, PC ;
Delong, DM ;
Tapson, VF .
RADIOLOGY, 1998, 209 (03) :689-695