A flexible registration and evaluation engine (f.r.e.e.)

被引:9
作者
Floca, Ralf [1 ]
Dickhaus, Hartmut [1 ]
机构
[1] Heidelberg Univ, Inst Med Biometry & Informat, Dept Med Informat, D-69120 Heidelberg, Germany
关键词
image registration; matching; evaluation; framework; parameterization; parameter optimization;
D O I
10.1016/j.cmpb.2007.04.009
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present an image registration framework which offers effective assistance for solving current registration problems. This work was motivated by the huge amount of registration problems in clinical applications and the problem of finding adequate solutions and properly comparing them. We have therefore designed a framework that supports the establishment, evaluation and comparison of registration approaches. Flexible registration and evaluation engine (f.r.e.e) achieves a broad basis of algorithms by utilizing the insight segmentation and registration toolkit (ITK). This basis can be extended by virtually any new approach or algorithm, which then becomes seamlessly integrated into the method set of the f.r.e.e. framework. The framework offers suitable tools for an easy integration, optimization and proper evaluation of registration approaches, as well as an efficient utilization of the results in clinical routine. The framework is currently being evaluated at the Heidelberg University Hospital, Germany. The first results were gathered with an application implemented for the Neurosurgical Department of the hospital. In these tests the framework concept, along with its specific tools, was very promising for establishing clinical applications (e.g. preoperative neurosurgical planning; registration of cardiac images) and therefore motivated further development. The ability to automatically optimize the parameterization of registration methods regarding a given test set also proved useful, allowing more concentration on scientific problems themselves and not on the laborious task of parameter tweaking. Due to implemented abstraction layers, f.r.e.e. also allows a high degree of transparency and thus good comparability of registration approaches and results. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:81 / 92
页数:12
相关论文
共 35 条
[21]  
MATTES D, 2001, NONRIGID MULTIMODALI, P1609
[22]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[23]  
Powell M. J. D., 1998, Acta Numerica, V7, P287, DOI 10.1017/S0962492900002841
[24]  
Spall JC, 1998, J HOPKINS APL TECH D, V19, P482
[25]   Parametric estimate of intensity inhomogeneities applied to MRI [J].
Styner, M ;
Brechbühler, C ;
Székely, G ;
Gerig, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (03) :153-165
[26]  
Thirion J P, 1998, Med Image Anal, V2, P243, DOI 10.1016/S1361-8415(98)80022-4
[27]   Splines - A perfect fit for signal and image processing [J].
Unser, M .
IEEE SIGNAL PROCESSING MAGAZINE, 1999, 16 (06) :22-38
[28]  
Wells W M 3rd, 1996, Med Image Anal, V1, P35
[29]   Comparison and evaluation of retrospective intermodality brain image registration techniques [J].
West, J ;
Fitzpatrick, JM ;
Wang, MY ;
Dawant, BM ;
Maurer, CR ;
Kessler, RM ;
Maciunas, RJ ;
Barillot, C ;
Lemoine, D ;
Collignon, A ;
Maes, F ;
Suetens, P ;
Vandermeulen, D ;
vandenElsen, PA ;
Napel, S ;
Sumanaweera, TS ;
Harkness, B ;
Hemler, PF ;
Hill, DLG ;
Hawkes, DJ ;
Studholme, C ;
Maintz, JBA ;
Viergever, MA ;
Malandain, G ;
Pennec, X ;
Noz, ME ;
Maguire, GQ ;
Pollack, M ;
Pelizzari, CA ;
Robb, RA ;
Hanson, D ;
Woods, RP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) :554-566
[30]  
Wolpert D. H., 1997, IEEE Transactions on Evolutionary Computation, V1, P67, DOI 10.1109/4235.585893