Effect of working pressure on the structure and the electrochemical corrosion behavior of diamond-like carbon (DLC) coatings on the NiTi alloys

被引:31
作者
Cai, W.
Sui, J. H.
机构
[1] Harbin Inst Technol, Sch Mat Sci & Engn, Harbin 150001, Peoples R China
[2] Jiamusi Univ, Sch Mat Sci & Engn, Jiamusi 154007, Peoples R China
基金
中国国家自然科学基金;
关键词
NiTi alloys; diamond-like carbon; plasma immersion ion implantation and deposition; corrosion resistance;
D O I
10.1016/j.surfcoat.2006.07.164
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
DLC coatings with different working pressure (2 x 0(-2), 6 x 10(-2) and 8 x 10(-2) Pa) were deposited on polished NiTi alloys by plasma immersion ion implantation and deposition (PIIID) using graphite as plasma source. The results of Raman spectra and X-ray photoelectron spectroscopy (XPS) indicate the sp(3)/sp(2) ratio is decreased with the increase of the working pressure. The cross-section microstructure of the DLC coated NiTi alloys indicates that the DLC coating is dense and compact. The corrosion results show that the corrosion resistance of the NiTi alloys is improved by the DLC coating, and the corrosion resistance of the DLC coatings on the NiTi alloys is decreased with the increase of the working pressure. It can be concluded that the sp(3)/sp(2) ratio has obvious effect on the corrosion resistance of the DLC coatings. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:5194 / 5197
页数:4
相关论文
共 17 条
[11]  
MELTON KN, 1994, SMST 94, P187
[12]  
QI J, 2000, SURF COAT TECH, V128, P324
[13]   THE CORROSION BEHAVIOR OF NICKEL TITANIUM SHAPE MEMORY ALLOYS [J].
RONDELLI, G ;
VICENTINI, B ;
GIGADA, A .
CORROSION SCIENCE, 1990, 30 (8-9) :805-812
[14]   Tribological characterisation of diamond-like carbon coatings on Co-Cr-Mo alloy for orthopaedic applications [J].
Sheeja, D ;
Tay, BK ;
Lau, SP ;
Nung, LN .
SURFACE & COATINGS TECHNOLOGY, 2001, 146 :410-416
[15]   Corrosion behavior of heat-treated intermetallic titanium-nickel in hydrochloric acid solutions [J].
Starosvetsky, D ;
Khaselev, O ;
Yahalom, J .
CORROSION, 1998, 54 (07) :524-530
[16]   Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy [J].
Uo, M ;
Watari, F ;
Yokoyama, A ;
Matsuno, H ;
Kawasaki, T .
BIOMATERIALS, 1999, 20 (08) :747-755
[17]   The effect of negative bias pulse on the bonding configurations and properties of DLC films prepared by PBII with acetylene [J].
Xia, LF ;
Sun, MR ;
Liao, JX .
DIAMOND AND RELATED MATERIALS, 2005, 14 (01) :42-47