Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer

被引:91
作者
Boujtita, M
Hart, JP
Pittson, R
机构
[1] Univ W England, Fac Sci Appl, Bristol BS1 6QY, Avon, England
[2] Gwent Elect Mat Ltd, Pontypridd PR4 0HZ, M Glam, Wales
关键词
screen-printed; chronoamperometry; amperometry; ethanol; biosensor; beer;
D O I
10.1016/S0956-5663(00)00075-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A disposable amperometric biosensor for the measurement of ethanol has been developed. It comprises a screen-printed carbon electrode doped with 5% cobalt phthalocyanine (CoPC-SPCE), and coated with alcohol oxidase; a permselective membrane on the surface acts as a barrier to interferents. The measurement of ethanol is based on the signal produced by H2O2, the product of the enzymatic reaction. Optimisation studies were performed using amperometry in stirred solution and the magnitude of the signal was found to be dependent on pH, enzyme loading, type of membrane and applied potential. The same technique was used to evaluate the biosensor for the determination of ethanol in samples. The results obtained compared well with the manufacturers specifications. In order to test the possibility of using the devices in the held, chronoamperometry was also used to determine ethanol in the same beer samples. The precision and recovery data again indicated that the biosensor should give reliable results under the conditions described. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 30 条
  • [1] Biosensors for analysis of ethanol in food: Effect of the pasting liquid
    Boujtita, M
    Chapleau, M
    ElMurr, N
    [J]. ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 91 - 96
  • [2] BIOSENSORS FOR ANALYSIS OF ETHANOL IN FOODS
    BOUJTITA, M
    ELMURR, N
    [J]. JOURNAL OF FOOD SCIENCE, 1995, 60 (01) : 201 - 204
  • [3] Amperometric biosensor for ethanol based on immobilization of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode
    Cai, CX
    Xue, KH
    Zhou, YM
    Yang, H
    [J]. TALANTA, 1997, 44 (03) : 339 - 347
  • [4] Castanon MJL, 1997, BIOSENS BIOELECTRON, V12, P511
  • [5] DETERMINATION OF ETHANOL IN BEER BY DIRECT-INJECTION GAS-CHROMATOGRAPHY - A COMPARISON OF 6 IDENTICAL SYSTEMS
    CLARKSON, SP
    ORMROD, IHL
    SHARPE, FR
    [J]. JOURNAL OF THE INSTITUTE OF BREWING, 1995, 101 (03) : 191 - 193
  • [6] Direct monitoring of formaldehyde vapour and detection of ethanol vapour using dehydrogenase-based biosensors
    Dennison, MJ
    Hall, JM
    Turner, APF
    [J]. ANALYST, 1996, 121 (12) : 1769 - 1773
  • [7] REAGENTLESS CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODE BASED ON A PHENOTHIAZINE POLYMER DERIVATIVE AND YEAST ALCOHOL-DEHYDROGENASE FOR THE ANALYSIS OF ETHANOL
    DOMINGUEZ, E
    LAN, HL
    OKAMOTO, Y
    HALE, PD
    SKOTHEIM, TA
    GORTON, L
    HAHNHAGERDAL, B
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4) : 229 - 237
  • [8] DUBOWSKI KM, 1982, ALCOHOL ANAL CLIN LA
  • [9] VOLTAMMETRIC AND PHOTOELECTRON SPECTRAL ELUCIDATION OF THE ELECTROCATALYTIC OXIDATION OF HYDROGEN-PEROXIDE AT SCREEN-PRINTED CARBON ELECTRODES CHEMICALLY-MODIFIED WITH COBALT PHTHALOCYANINE
    GILMARTIN, MAT
    EWEN, RJ
    HART, JP
    HONEYBOURNE, CL
    [J]. ELECTROANALYSIS, 1995, 7 (06) : 547 - 555
  • [10] PROTOTYPE, SOLID-PHASE, GLUCOSE BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    PATTON, DT
    [J]. ANALYST, 1995, 120 (07) : 1973 - 1981