Electromagnetic wave compression and radio frequency homogeneity in NMR solenoidal coils: Computational approach

被引:39
作者
Engelke, F [1 ]
机构
[1] Bruker Biospin GmbH, D-76287 Rehinstetten, Germany
来源
CONCEPTS IN MAGNETIC RESONANCE | 2002年 / 15卷 / 02期
关键词
electromagnetic fields; helical waveguides; Maxwell equations; wave compression; solenoidal coils; NMR; balanced circuits; radio frequency held distribution;
D O I
10.1002/cmr.10029
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The homogeneity of the radio frequency (RF) magnetic field in the region of the NMR sample is prerequisite for good performance in many NMR experiments. When calculating such fields, the quasistationary approximation is valid for wavelengths that are large compared to the physical dimensions of the NMR coil, but it no longer applies for the geometrical dimensions of NMR coils at high frequencies. The present study investigates electromagnetic fields in solenoidal coils. Considering the electromagnetic field derivable from first principles allows us to systematically study the effects that originate from the finiteness of the wavelength compared to the physical size of solenoidal coils employed in NMR probes. There are three major effects that occur: the wavelength in the coil is generally different from the wavelength in free space, even for an absent sample; the dielectric properties of the NMR sample have an additional influence on the electromagnetic field distribution inside the coil; and the circuit surrounding the coil leads to a wave reflection that affects the RF magnetic field distribution originating from the superposition of forward and backward traveling waves. The results allow the derivation of principal conclusions for the characterization of NMR solenoidal coils. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:129 / 155
页数:27
相关论文
共 36 条
[11]   NMR frequency shift under sample spinning [J].
Goldman, M ;
Fleury, V ;
Gueron, M .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 118 (01) :11-20
[12]   A method for determining B1 field inhomogeneity.: Are the biases assumed in heteronuclear relaxation experiments usually underestimated? [J].
Guenneugues, M ;
Berthault, P ;
Desvaux, H .
JOURNAL OF MAGNETIC RESONANCE, 1999, 136 (01) :118-126
[13]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85
[14]   Application of finite difference time domain method for the design of birdcage RF head coils using multi-port excitations [J].
Ibrahim, TS ;
Lee, R ;
Baertlein, BA ;
Kangarlu, A ;
Robitaille, PML .
MAGNETIC RESONANCE IMAGING, 2000, 18 (06) :733-742
[15]   DESIGN AND CONSTRUCTION OF A HIGH HOMOGENEITY RF COIL FOR SOLID-STATE MULTIPLE-PULSE NMR [J].
IDZIAK, S ;
HAEBERLEN, U .
JOURNAL OF MAGNETIC RESONANCE, 1982, 50 (02) :281-288
[16]   Adiabatic TOCSY MAS in liquids [J].
Kupce, E ;
Keifer, PA ;
Delepierre, M .
JOURNAL OF MAGNETIC RESONANCE, 2001, 148 (01) :115-120
[17]  
LANGE K, 1992, MEINKE GUNDLACH TASC, pK41
[18]  
MAGNUSSON PC, 1992, TRANSMISSION LINES W, P351
[19]   A NOVEL-APPROACH TO THE CALCULATION OF RF MAGNETIC AND ELECTRIC-FIELDS FOR NMR COILS OF ARBITRARY GEOMETRY [J].
MAHONY, C ;
FORBES, LK ;
CROZIER, S ;
DODDRELL, DM .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 107 (02) :145-151
[20]  
Minard KR, 2001, CONCEPT MAGNETIC RES, V13, P128, DOI 10.1002/1099-0534(2001)13:2<128::AID-CMR1002>3.0.CO