Fabrication and characterization of 3D hydrogel microarrays to measure antigenicity and antibody functionality for biosensor applications

被引:87
作者
Charles, PT [1 ]
Goldman, ER [1 ]
Rangasammy, JG [1 ]
Schauer, CL [1 ]
Chen, MS [1 ]
Taitt, CR [1 ]
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
关键词
D O I
10.1016/j.bios.2004.04.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report the fabrication, characterization and evaluation of three-dimensional (3D) hydrogel thin films used to measure protein binding (antigenicity) and antibody functionality in a microarray format. Protein antigenicity was evaluated using the protein toxin, staphylococcal enterotoxin B (SEB), as a model on highly crosslinked hydrogel thin films of polyacrylamide and on two-dimensional (2D) glass surfaces. Covalent crosslinking conditions were optimized and quantified. Interrogation of the modified 3D hydrogel was measured both by direct coupling of a Cy5-labeled SEB molecule and Cy5-anti-SEB antibody binding to immobilized unlabeled SEB. Antibody functionality experiments were conducted using three chemically modified surfaces (highly crosslinked polyacrylamide hydrogels, commercially available hydrogels and 2D glass surfaces). Cy3-labeled anti-mouse IgG (capture antibody) was microarrayed onto the hydrogel surfaces and interrogated with the corresponding Cy5-labeled mouse IgG (antigen). Five different concentrations of Cy5-labeled mouse IgG were applied to each microarrayed surface and the fluorescence quantified by scanning laser confocal microscopy. Experimental results showed fluorescence intensities 3-10-fold higher for the 3D films compared to analogous 2D surfaces with attomole level sensitivity measured in direct capture immunoassays. However, 2D surfaces reported equal or greater sensitivity on a per-molecule basis. Reported also are the immobilization efficiencies, inter-and intra-slide variability and detection limits. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:753 / 764
页数:12
相关论文
共 55 条
[1]   3D protein microarrays:: Performing multiplex immunoassays on a single chip [J].
Angenendt, P ;
Glökler, J ;
Konthur, Z ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL CHEMISTRY, 2003, 75 (17) :4368-4372
[2]   Toward optimized antibody microarrays:: a comparison of current microarray support materials [J].
Angenendt, P ;
Glökler, J ;
Murphy, D ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :253-260
[3]   Protein microchips: Use for immunoassay and enzymatic reactions [J].
Arenkov, P ;
Kukhtin, A ;
Gemmell, A ;
Voloshchuk, S ;
Chupeeva, V ;
Mirzabekov, A .
ANALYTICAL BIOCHEMISTRY, 2000, 278 (02) :123-131
[4]   Biological microchips with hydrogel-immobilized nucleic acids, proteins, and other compounds: Properties and applications in genomics [J].
Barsky, VE ;
Kolchinsky, AM ;
Lysov, YP ;
Mirzabekov, AD .
MOLECULAR BIOLOGY, 2002, 36 (04) :437-455
[5]   Protein patterning [J].
Blawas, AS ;
Reichert, WM .
BIOMATERIALS, 1998, 19 (7-9) :595-609
[6]   Protein and antibody arrays and their medical applications [J].
Cahill, DJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 250 (1-2) :81-91
[7]   ORIENTATION OF ACID-PRETREATED ANTIBODIES ON HYDROPHOBIC DICHLORODIMETHYLSILANE-TREATED SILICA SURFACES [J].
CHANG, IN ;
HERRON, JN .
LANGMUIR, 1995, 11 (06) :2083-2089
[8]   Immobilization strategy and characterization of hydrogel-based thin films for interrogation of ligand binding with staphylococcal enterotoxin B (SEB) in a protein microarray format [J].
Charles, PT ;
Taitt, CR ;
Goldman, ER ;
Rangasammy, JG ;
Stenger, DA .
LANGMUIR, 2004, 20 (01) :270-272
[9]   Covalent attachment of synthetic DNA to self-assembled monolayer films [J].
Chrisey, LA ;
Lee, GU ;
OFerrall, CE .
NUCLEIC ACIDS RESEARCH, 1996, 24 (15) :3031-3039
[10]   Comparison of chemical cleaning methods of glass in preparation for silanization [J].
Cras, JJ ;
Rowe-Taitt, CA ;
Nivens, DA ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (8-9) :683-688