摘要
The surface chemical composition and chemical state of Ti-50.6 at.% Ni alloy samples coated with tantalum by an arc ion plating method were investigated by X-ray photoelectron spectroscopy (XPS). The results of XPS survey and high resolution spectra show that a thin oxide film with Ta2O5 in the outmost layer and tantalum suboxides in the inner layer are formed on the tantalum coating as a result of natural passivation of Ta in the atmosphere. The Ni ion release with time from uncoated and coated samples immersed in 0.9%NaCl solution was also investigated by atomic absorption spectrometry (AAS). Compared to the coated samples, the uncoated samples show a higher release rate that decreases slightly with time. The degree of dissolution for the coated sample is reduced from 0.28 to 0.74 mug/cm(2) after 49 days, implying the coating has a beneficial effect on the inhabitation of Ni ion release from the TiNi substrate. The atomic force microscope (AFM) images and section analysis show that the root mean square (RMS) roughness increases from 10.349 to 65.587 run, and the maximum roughness (R-max) increases from 36.027 to 278.22 nm, confirming that immersion in the NaCl solution results in roughening of the coating surface. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:428 / 433
页数:6
相关论文
共 22 条
[1]   Stability of radiopaque iodine-containing biomaterials [J].
Aldenhoff, YBJ ;
Kruft, MAB ;
Pijpers, AP ;
van der Veen, FH ;
Bulstra, SK ;
Kuijer, R ;
Koole, LH .
BIOMATERIALS, 2002, 23 (03) :881-886
[2]   Metallic artifacts of coronary and iliac arteries stents in mr angiography and contrast-enhanced CT [J].
Amano, Y ;
Ishihara, M ;
Hayashi, H ;
Gemma, K ;
Kawamata, H ;
Amano, M ;
Kumazaki, T .
CLINICAL IMAGING, 1999, 23 (02) :85-89
[3]  
BINCH JG, 1999, P 1 EUR C SHAP MEM S, P154
[4]   Antithrombogenic investigation of surface energy and optical bandgap and hemocompatibility mechanism of Ti(Ta+5)O2 thin films [J].
Chen, JY ;
Leng, YX ;
Tian, XB ;
Wang, LP ;
Huang, N ;
Chu, PK ;
Yang, P .
BIOMATERIALS, 2002, 23 (12) :2545-2552
[5]   Corrosion property of TiNi shape memory alloys coated with tantalum [J].
Cheng, Y ;
Cai, W ;
Li, HT ;
Zhao, LC .
JOURNAL OF MATERIALS SCIENCE LETTERS, 2003, 22 (23) :1681-1683
[6]  
DUERIG T, 1999, STRUCT MAT PROP MICR, V273, P149
[7]   An overview of superelastic stent design [J].
Duerig, TW ;
Tolomeo, DE ;
Wholey, M .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2000, 9 (3-4) :235-246
[8]   Influence of the surface structure of titanium materials on the adhesion of fibroblasts [J].
Eisenbarth, E ;
Meyle, J ;
Nachtigall, W ;
Breme, J .
BIOMATERIALS, 1996, 17 (14) :1399-1403
[9]  
HODGSON DE, 1997, P 2 INT C SHAP MEM S, P461
[10]   Tantalum as a buffer layer in diamond-like carbon coated artificial hip joints [J].
Kiuru, M ;
Alakoski, E ;
Tiainen, VM ;
Lappalainen, R ;
Anttila, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 66B (01) :425-428