Evaluation of mercuric iodide ceramic semiconductor detectors

被引:13
作者
Schieber, M [1 ]
Zuck, A
Braiman, M
Nissenbaum, J
Turchetta, R
Dulinski, W
Husson, D
Riester, JL
机构
[1] Hebrew Univ Jerusalem, IL-91904 Jerusalem, Israel
[2] ULP, IN2P3, LEPSI, Strasbourg, France
[3] Sandia Natl Labs, Livermore, CA 94550 USA
关键词
D O I
10.1016/S0920-5632(97)00581-1
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Mercuric iodide ceramic radiation detectors, which can act as nuclear particle counters, have been fabricated with single continuos electrical contacts and with linear strip contacts. They have been tested with different kinds of gamma and beta sources as well as in a high energy beam at CERN. The detectors were also successfully tested for radiation hardness with irradiation of 5(double dagger)10(14) neutrons/cm(2). The ratio of detected photons over the number of absorbed photons has been measured with gamma sources of different energies, and it ranges from 20% at 44 keV up to about 30% at 660 keV. An absolute efficiency of 70% has been measured for a 350 mu m thick detector for beta particles emitted by a Sr-90 source. Charge collection efficiency, defined as the amount of charge induced on the electrodes by a Minimum Ionizing Particle (MIP) traversing the detector, has been measured in two samples. The average collected charge fits well with a linear curve with slope of 35 electrons/(kV/cm) per 100 mu m. This result is well described by a dynamic device simulation, where the free carrier mean lifetime is used as a free parameter, adjusted to a value of 1.5 ns, i.e. about 1/100 of the corresponding lifetime in single crystal HgI2 detectors. The response to MIP has also been studied with a high energy (100 GeV) muon beam in CERN. A preliminary beam profile is presented while a more detailed analysis is still in progress and will be presented elsewhere. These results together with the low cost of the material make ceramic HgI2 detectors excellent candidates for large area particle tracking and imaging applications, even in a radiation harsh environment.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 14 条
[1]   HADRON FLUXES IN INNER PARTS OF LHC DETECTORS [J].
AARNIO, PA ;
HUHTINEN, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2) :98-105
[2]  
COLLEDANI, UNPUB NUCL INST ME A
[3]   A submicron precision silicon telescope for beam test purposes [J].
Colledani, C ;
Dulinski, W ;
Turchetta, R ;
Djama, F ;
Rudge, A ;
Weilhammer, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 372 (03) :379-384
[4]   CASTOR a VLSI CMOS mixed analog-digital circuit for low noise multichannel counting applications [J].
Comes, G ;
Loddo, F ;
Hu, Y ;
Kaplon, J ;
Ly, F ;
Turchetta, R ;
Bonvicini, V ;
Vacchi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :440-445
[5]  
JAMES RB, 1995, SEMICONDUCTORS ROOM, P336
[6]  
PAN LS, 1995, MAT RES SOC FALL M B
[7]   BULK AND SURFACE STOICHIOMETRY OF VAPOR-GROWN MERCURIC IODIDE-CRYSTALS [J].
SCHIEBER, M ;
ROTH, M ;
YAO, H ;
DEVRIES, M ;
JAMES, RB ;
GOORSKY, M .
JOURNAL OF CRYSTAL GROWTH, 1995, 146 (1-4) :15-22
[8]   Material properties and room-temperature nuclear detector response of wide bandgap semiconductors [J].
Schieber, M ;
Lund, JC ;
Olsen, RW ;
McGregor, DS ;
VanScyoc, JM ;
James, RB ;
Soria, E ;
Bauser, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :492-495
[9]  
SCHIEBER M, 1994, Patent No. 111085
[10]  
SCHIEBER M, 1995, IN PRESS NUCL INST M