ToF-SIMS Depth Profiling of Organic Films: A Comparison between Single-Beam and Dual-Beam Analysis

被引:58
作者
Brison, J. [1 ]
Muramoto, S. [1 ]
Castner, David G. [1 ,2 ]
机构
[1] Univ Washington, Dept Chem Engn, Natl ESCA & Surface Anal Ctr Biomed Problems, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Natl ESCA & Surface Anal Ctr Biomed Problems, Seattle, WA 98195 USA
关键词
ION MASS-SPECTROMETRY; PLASMA DEPOSITION; C-60; IMPACT; BUCKMINSTERFULLERENE; TETRAGLYME; CHALLENGES; EMISSION; DYNAMICS; SPUTTER;
D O I
10.1021/jp9066179
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In dual-beats depth profiling, a high energy analysis beans and a lower energy etching beam are operated in series. Although the fluence of the analysis beam is usually kept well below the static SIMS limit, complete removal of the damage. induced by the high energy analysis beans while maintaining a good depth resolution is difficult. In this study, a plasma polymerized tetraglyme film is used as the model organic system and the dimensionless parameter R, (analysis beam fluence)/(total ion fluence), is introduced to quantify file degree of sample damage induced as a function of the analysis beans fluence. For a constant C-60(+) etching beans fluence, increasing the analysis fluence (and consequently increasing the R parameter) increased the amount of damage accumulated in the sample. For Bi-n(+) (n = 1 and 3) and C-60(+) depth profiling, minimal damage accumulation was observed up to R = 0.03, with a best depth resolution of 8 nm. In general, an increase in the Bi-n(+) analysis fluence above this value resulted ill a decrease in the molecular signals of file steady state region of the depth profile and a degradation of the depth resolution at the polymer/substrate interface.
引用
收藏
页码:5565 / 5573
页数:9
相关论文
共 43 条
[1]   SPUTTERING STUDIES WITH THE MONTE-CARLO PROGRAM TRIM.SP [J].
BIERSACK, JP ;
ECKSTEIN, W .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1984, 34 (02) :73-94
[2]   Biological tissue imaging with time-of-flight secondary ion mass spectrometry and cluster ion sources [J].
Brunelle, A ;
Touboul, D ;
Laprévote, O .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (08) :985-999
[3]   Molecular depth profiling with cluster ion beams [J].
Cheng, J ;
Wucher, A ;
Winograd, N .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (16) :8329-8336
[4]   Sputtering of thin benzene and polystyrene overlayers by keV Ga and C60 bombardment [J].
Czerwinski, B. ;
Delcorte, A. ;
Garrison, Bt ;
Samson, R. ;
Winograd, N. ;
Postawa, Z. .
APPLIED SURFACE SCIENCE, 2006, 252 (19) :6419-6422
[5]   Energy distributions of atomic and molecular ions sputtered by C60+ projectiles [J].
Delcorte, A. ;
Poleunis, C. ;
Bertrand, P. .
APPLIED SURFACE SCIENCE, 2006, 252 (19) :6542-6546
[6]   C60, buckminsterfullerene:: its impact on biological ToF-SIMS analysis [J].
Fletcher, John S. ;
Lockyer, Nicholas P. ;
Vickerman, John C. .
SURFACE AND INTERFACE ANALYSIS, 2006, 38 (11) :1393-1400
[7]   Uncovering new challenges in bio-analysis with ToF-SIMS [J].
Fletcher, John S. ;
Henderson, Alex ;
Biddulph, Gregory X. ;
Vaidyanathan, Seetharaman ;
Lockyer, Nicholas P. ;
Vickerman, John C. .
APPLIED SURFACE SCIENCE, 2008, 255 (04) :1264-1270
[8]   MOLECULAR ION IMAGING AND DYNAMIC SECONDARY ION MASS-SPECTROMETRY OF ORGANIC-COMPOUNDS [J].
GILLEN, G ;
SIMONS, DS ;
WILLIAMS, P .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2122-2130
[9]  
Gillen G, 1998, RAPID COMMUN MASS SP, V12, P1303, DOI 10.1002/(SICI)1097-0231(19981015)12:19<1303::AID-RCM330>3.0.CO
[10]  
2-7