What is the optimum leaf width of a multileaf collimator?

被引:87
作者
Bortfeld, T [1 ]
Oelfke, U [1 ]
Nill, S [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Dept Phys Med, D-69120 Heidelberg, Germany
关键词
multileaf collimator; sampling; leaf width; isocenter shift;
D O I
10.1118/1.1319524
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The following question is investigated: How narrow do the leaves of a multileaf collimator have to be such that further reduction of the leaf width does not lead to physical improvements of the dose distribution. Because of the physical principles of interaction between radiation and matter, dose distributions in radiotherapy are generally relatively smoothe According to the theory of sampling, the dose distribution can therefore be represented by a set of evenly spaced samples. The distance between the samples is identified with the distance between the leaf centers of a multileaf collimator. The optimum sampling distance is derived from the 20% to 80% field edge penumbra through the concept of the dose deposition kernel, which is approximated by a Gaussian. The leaf width of the multileaf collimator is considered to be independent from the sampling distance. Two cases are studied in detail: (i) the leaf width equals the sampling distance, which is the regular case, and (ii) the leaf width is twice the sampling distance. The practical delivery of the latter treatment geometry requires a couch movement or a collimator rotation. The optimum sampling distance equals the 20%-80% penumbra divided by 1.7 and is on the order of 1.5-2 mm for a typical 6 MV beam in soft tissue. The optimum leaf width equals this sampling distance in the regular case. A relatively small deterioration results if the leaf width is doubled, while the sampling distance remains the same. The deterioration can be corrected for by deconvolving the fluence profile with an inverse tilter. Conclusions: With the help of the sampling theory and, more generally, the theory of linear systems, one can find a general answer to the question about the optimum leaf width of a multileaf collimator from a physical point of view. It is important to distinguish between the sampling distance and the leaf width. The sampling distance is more critical than the leaf width. The leaf width can be up to twice as large as the sampling width. Furthermore, the derived sampling distance can be used to select the optimum resolution of both the fluence and the dose grid in dose calculation and inverse planning algorithms. (C) 2000 American Association of Physicists in Medicine. [S0094-2405 (00)02011-3].
引用
收藏
页码:2494 / 2502
页数:9
相关论文
共 25 条
[1]   Dose calculations for external photon beams in radiotherapy [J].
Ahnesjö, A ;
Aspradakis, MM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :R99-R155
[2]   DECOMPOSITION OF PENCIL BEAM KERNELS FOR FAST DOSE CALCULATIONS IN 3-DIMENSIONAL TREATMENT PLANNING [J].
BORTFELD, T ;
SCHLEGEL, W ;
RHEIN, B .
MEDICAL PHYSICS, 1993, 20 (02) :311-318
[3]  
BORTFELD T, 1997, 12 INT C US COMP RAD, P1
[4]  
Bracewell R. N., 1986, FOURIER TRANSFORM IT, V31999
[5]   Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery [J].
Cosgrove, VP ;
Jahn, U ;
Pfaender, M ;
Bauer, S ;
Budach, V ;
Wurm, RE .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :325-336
[6]   A pencil-beam photon dose algorithm for stereotactic radiosurgery using a miniature multileaf collimator [J].
Dong, L ;
Shiu, AM ;
Tung, S ;
Hogstrom, K .
MEDICAL PHYSICS, 1998, 25 (06) :841-850
[7]   A method of improving the spatial resolution of treatments that involve a multileaf collimator [J].
Evans, PM ;
Partridge, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03) :609-622
[8]   Field edge smoothing for multileaf collimators [J].
Galvin, JM ;
Leavitt, DD ;
Smith, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (01) :89-94
[9]   CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM [J].
GALVIN, JM ;
SMITH, AR ;
LALLY, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :181-192
[10]   Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans [J].
Kubo, HD ;
Wilder, RB ;
Pappas, CTE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (04) :937-945