Can the body slope of interference screw affect initial stability of reconstructed anterior cruciate ligament?: An in-vitro investigation

被引:10
作者
Daneshvarhashjin, Nazanin [1 ,2 ]
Chizari, Mahmoud [3 ,4 ]
Mortazavi, Javad [5 ]
Rouhi, Gholamreza [1 ]
机构
[1] Amirkabir Univ Technol, Fac Biomed Engn, Tehran, Iran
[2] Katholieke Univ Leuven, Fac Med, Dept Biomed Sci, Inst Orthopaed Res & Training, Leuven, Belgium
[3] Sharif Univ Technol, Fac Mech Engn, Tehran, Iran
[4] Univ Hertfordshire, Sch Phys Engn & Comp Sci, Hatfield, Herts, England
[5] Univ Tehran Med Sci, Joint Reconstruct Res Ctr, Tehran, Iran
关键词
ACL Injury and Reconstruction; Initial Stability; Bio-mimicked Interference Screw; Body Slope; Graft Damage; Graft Laxity; In-vitro Mechanical Tests; BONE TUNNEL; FIT FIXATION; METAANALYSIS; STRENGTH; EXTENSOR; FAILURE; GRAFTS; LENGTH;
D O I
10.1186/s12891-021-04446-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
BackgroundSuperior biomechanical performance of tapered interference screws, compared with non-tapered screws, with reference to the anterior cruciate ligament (ACL) reconstruction process, has been reported in the literature. However, the effect of tapered interference screw's body slope on the initial stability of ACL is poorly understood. Thus, the main goal of this study was to investigate the effect of the interference screw's body slope on the initial stability of the reconstructed ACL.MethodsBased on the best screw-bone tunnel diameter ratios in non-tapered screws, two different tapered interference screws were designed and fabricated. The diameters of both screws were equal to bone tunnel diameter in one-third of their length from screw tip, then they were gradually increased by 1mm, in the lower slope (LSTIS), and 2 mm, in the higher slope (HSTIS) screws. To simulate the ACL reconstruction, sixteen soft tissue grafts were fixed, using HSTIS and LSTIS, in synthetic bone blocks. Through applying sub-failure cyclic incremental tensile load, graft-bone-screw construct's stiffness and graft laxity in each cycle, also through applying subsequent step of loading graft to the failure, maximum load to failure, and graft's mode of failure were determined. Accordingly, the performance of the fabricated interference screws was compared with each other.ResultsHSTIS provides a greater graft-bone-screw construct stiffness, and a lower graft laxity, compared to LSTIS. Moreover, transverse rupture of graft fibers for LSTIS, and necking of graft in the HSTIS group were the major types of grafts' failure.ConclusionsHSTIS better replicates the intact ACL's behavior, compared to LSTIS, by causing less damage in graft's fibers; reducing graft laxity; and increasing fixation stability. Nonetheless, finding the optimal slope remains as an unknown and can be the subject of future studies.
引用
收藏
页数:10
相关论文
共 39 条
[1]
Biomechanical Comparison of Interference Screws and Combination Screw and Sheath Devices for Soft Tissue Anterior Cruciate Ligament Reconstruction on the Tibial Side [J].
Aga, Cathrine ;
Rasmussen, Matthew T. ;
Smith, Sean D. ;
Jansson, Kyle S. ;
LaPrade, Robert F. ;
Engebretsen, Lars ;
Wijdicks, Coen A. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (04) :841-848
[2]
Antoniac I, 2013, Biologically Responsive Biomaterials for Tissue Engineering, P107
[3]
Biomechanical analysis of an interference screw and a novel twist lock screw design for bone graft fixation [J].
Asnis, S. ;
Mullen, J. ;
Asnis, P. D. ;
Sgaglione, N. ;
LaPorta, T. ;
Grande, D. A. ;
Chahine, N. O. .
CLINICAL BIOMECHANICS, 2017, 50 :99-104
[4]
Emerging Trends in Anterior Cruciate Ligament Reconstruction [J].
Budny, Jacob ;
Fox, Joseph ;
Rauh, Michael ;
Fineberg, Marc .
JOURNAL OF KNEE SURGERY, 2017, 30 (01) :63-69
[5]
Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods [J].
Carulli, Christian ;
Matassi, Fabrizio ;
Soderi, Stefano ;
Sirleo, Luigi ;
Munz, Giovanni ;
Innocenti, Massimo .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (04) :1264-1271
[6]
Magnesium inference screw supports early graft incorporation with inhibition of graft degradation in anterior cruciate ligament reconstruction [J].
Cheng, Pengfei ;
Han, Pei ;
Zhao, Changli ;
Zhang, Shaoxiang ;
Zhang, Xiaonong ;
Chai, Yimin .
SCIENTIFIC REPORTS, 2016, 6
[7]
Post-operative analysis of ACL tibial fixation [J].
Chizari, Mahmoud ;
Snow, Martyn ;
Wang, Bin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (07) :730-736
[8]
Biomechanics of the anterior cruciate ligament and implications for surgical reconstruction [J].
Dargel, J. ;
Gotter, M. ;
Mader, K. ;
Pennig, D. ;
Koebke, J. ;
Schmidt-Wiethoff, R. .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2007, 2 (01) :1-12
[9]
Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies? [J].
Domnick, C. ;
Wieskoetter, B. ;
Raschke, M. J. ;
Schulze, M. ;
Kronenberg, D. ;
Wefelmeier, M. ;
Langer, M. F. ;
Herbort, M. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (10) :1465-1471
[10]
Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons [J].
Donahue, TLH ;
Gregersen, C ;
Hull, ML ;
Howell, SM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (02) :162-169