Measurement of the point spread function in MRI using constant time imaging

被引:110
作者
Robson, MD
Gore, JC
Constable, RT
机构
[1] Department of Diagnostic Radiology, Yale University, School of Medicine, New Haven, CT
[2] Yale University, School of Medicine, Department of Diagnostic Radiology, New Haven, CT 06520-8042
关键词
point spread function; echo-planar imaging; constant time imaging; geometric distortion;
D O I
10.1002/mrm.1910380509
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The point spread function is a fundamental property of magnetic resonance imaging methods that affects image quality and spatial resolution. The point spread function is difficult to measure precisely in magnetic resonance even with the use of carefully designed phantoms, and it is difficult to calculate this function for complex sequences such as echo-planar imaging. This report describes a method that measures the point spread function with high spatial resolution at each pixel in samples of uniform intensity distribution, This method uses additional phase encoding gradients before the echo-planar acquisition that are constant in length but vary in amplitude. The additional gradients are applied to image the contents within each individual voxel, This method has been used to measure the point spread function for echo-planar imaging to demonstrate the effects of limited k-space sampling and transverse relaxation, as well as the effects of object motion, By considering the displacement of the point spread function, local distortions due to susceptibility and chemical shift effects have been quantified and corrected. The method allows rapid assessment of the point spread function in echo-planar imaging, in vivo, and may also be applied to other rapid imaging sequences that can be modified to include these additional phase encoding gradients.
引用
收藏
页码:733 / 740
页数:8
相关论文
共 21 条
[1]   HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1. [J].
AHN, CB ;
KIM, JH ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :2-7
[2]   ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING [J].
BUTTS, K ;
RIEDERER, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :285-293
[3]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[4]   THEORETICAL ASPECTS OF MOTION SENSITIVITY AND COMPENSATION IN ECHO-PLANAR IMAGING [J].
DUERK, JL ;
SIMONETTI, OP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06) :643-650
[5]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[6]   ECHO-PLANAR HIGH-RESOLUTION FLOW VELOCITY MAPPING [J].
FIRMIN, DN ;
KLIPSTEIN, RH ;
HOUNSFIELD, GL ;
PALEY, MP ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) :316-327
[7]   SENSITIVITY AND RESOLUTION OF CONSTANT-TIME IMAGING [J].
GRAVINA, S ;
CORY, DG .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 104 (01) :53-61
[8]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[9]  
JUDY P F, 1976, Medical Physics (Woodbury), V3, P233, DOI 10.1118/1.594283