Analysis of pharmaceutical formulations using atmospheric pressure ion mobility spectrometry combined with liquid chromatography and nano-electrospray ionisation

被引:31
作者
Budimir, Natali [1 ]
Weston, Daniel J. [1 ]
Creaser, Colin S. [1 ]
机构
[1] Nottingham Trent Univ, Sch Biomed & NAt Sci, Interdisciplinary Biomed Res Ctr, Nottingham NG11 8NS, England
关键词
D O I
10.1039/b612796g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The hyphenation of liquid chromatography with atmospheric pressure ion mobility spectrometry is reported using a custom-made dynamic nano-electrospray ionisation (nano-ESI) interface. The analysis of pharmaceutical actives is described, including beta blocker (timolol), antidepressant (paroxetine), analgesic (paracetamol) and opiate (codeine) preparations. On-line ultraviolet diode array (UV) spectroscopic detection was used prior to sample ionisation, to evaluate chromatographic and nano-ESI interface performance. Active drug responses were characterised by chromatographic retention time and electrophoretic ion mobility drift time, and selected ion mobility responses were used to evaluate method performance. Limits of detection for active drugs were in the low-nmol to pmol range. Quantitative responses were investigated using a series of standard solutions of caffeine, showing good linearity (R-2 = 0.9982, n = 6) and reproducibility (RSD = 2.3%, n = 6). The analysis of an over the counter pharmaceutical formulation demonstrates the potential of ion mobility spectrometry combined with liquid chromatography and nano-electrospray ionisation for the rapid determination of active drugs, as a result of the electrophoretic separation and selectivity afforded by IMS.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 28 条
[11]   PHOTOIONIZATION IN AIR WITH ION MOBILITY SPECTROMETRY USING A HYDROGEN DISCHARGE LAMP [J].
LEASURE, CS ;
FLEISCHER, ME ;
ANDERSON, GK ;
EICEMAN, GA .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2142-2147
[12]   Determination of parabens in pharmaceutical formulations by solid-phase microextraction-ion mobility spectrometry [J].
Lokhnauth, JK ;
Snow, NH .
ANALYTICAL CHEMISTRY, 2005, 77 (18) :5938-5946
[13]   PLASMA CHROMATOGRAPHY WITH LASER-PRODUCED IONS [J].
LUBMAN, DM ;
KRONICK, MN .
ANALYTICAL CHEMISTRY, 1982, 54 (09) :1546-1551
[14]   Evaluation of capillary liquid chromatography-electrospray ionization ion mobility spectrometry with mass spectrometry detection [J].
Matz, LM ;
Dion, HM ;
Hill, HH .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :59-68
[15]  
McMinn DG, 1990, J MICRUCOL SEP, V2, P188
[16]   Gas-phase conformers of the [M+2H]2+ ion of bradykinin investigated by combining high-field asymmetric waveform ion mobility spectrometry, hydrogen/deuterium exchange, and energy-loss measurements [J].
Purves, RW ;
Barnett, DA ;
Ells, B ;
Guevremont, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (16) :1453-1456
[17]   CORONASPRAY NEBULIZATION AND IONIZATION OF LIQUID SAMPLES FOR ION MOBILITY SPECTROMETRY [J].
SHUMATE, CB ;
HILL, HH .
ANALYTICAL CHEMISTRY, 1989, 61 (06) :601-606
[18]  
Spangler G. E., 1990, U.S. Patent, Patent No. [4,928,033, 4928033]
[19]   Gas phase separations of electrosprayed peptide libraries [J].
Srebalus, CA ;
Li, JW ;
Marshall, WS ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :3918-3927
[20]   ELECTROSPRAY MASS-SPECTROSCOPY OF MACROMOLECULE DEGRADATION IN ELECTROSPRAY [J].
TEER, D ;
DOLE, M .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1975, 13 (05) :985-995