Experimental validation of a finite element model of a composite tibia

被引:22
作者
Gray, H. A.
Zavatsky, A. B.
Taddei, F.
Cristofolini, L.
Gill, H. S.
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[2] Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[3] Univ Bologna, Fac Engn, DIEM, Bologna, Italy
[4] Nuffield Orthopaed Ctr NHS Trust, Dept Orthopaed Surg, Oxford, England
关键词
tibia; finite element analysis; bone; composite tibia; experimental validation; validated finite element model;
D O I
10.1243/09544119JEIM119
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Composite bones are synthetic models made to simulate the mechanical behaviour of human bones. Finite element (FE) models of composite bone can be used to evaluate new and modified designs of joint prostheses and fixation devices. The aim of the current study was to create an FE model of a composite tibia and to validate it against results obtained from a comprehensive set of experiments. For this, 17 strain rosettes were attached to a composite tibia (model 3101, Pacific Research Laboratories, Vashon, Washington, USA). Surface strains and displacements were measured under 13 loading conditions. Two FE models were created on the basis of computed tomography scans. The models differed from each other in the mesh and material properties assigned. The experiments were simulated on them and the results compared with experimental results. The more accurate model was selected on the basis of regression analysis. In general, experimental strain measurements were highly repeatable and compared well with published results. The more accurate model, in which the inner elements representing the foam were assigned isotropic material properties and the elements representing the epoxy layer were assigned transversely isotropic material properties, was able to simulate the mechanical behaviour of the tibia with acceptable accuracy. The regression line for all axial loads combined had a slope of 0.999, an intercept of -6.24 microstrain, and an R-2 value of 0.962. The root mean square error as a percentage was 5 per cent.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 16 条
[1]
Agarwal BhagwanD., 1990, ANAL PERFORMANCE FIB
[2]
Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[3]
A novel transducer for the measurement of cement-prosthesis interface forces in cemented orthopaedic devices [J].
Cristofolini, L ;
Marchetti, A ;
Cappello, A ;
Viceconti, M .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (07) :493-501
[4]
Mechanical validation of whole bone composite tibia models [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :279-288
[5]
Mechanical conditions in the internal stabilization of proximal tibial defects [J].
Duda, GN ;
Mandruzzato, F ;
Heller, M ;
Kassi, JP ;
Khodadadyan, C ;
Haas, NP .
CLINICAL BIOMECHANICS, 2002, 17 (01) :64-72
[6]
Mechanical boundary conditions of fracture healing: borderline indications in the treatment of unreamed tibial nailing [J].
Duda, GN ;
Mandruzzato, F ;
Heller, M ;
Goldhahn, J ;
Moser, R ;
Hehli, M ;
Claes, L ;
Haas, NP .
JOURNAL OF BIOMECHANICS, 2001, 34 (05) :639-650
[7]
FAGAN MJ, 1997, FINITE ELEMENT ANAL
[8]
Herakovich C.T., 1998, MECH FIBROUS COMPOSI
[9]
Perillo-Marcone A., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P17, DOI 10.1080/1025584031000064470
[10]
The importance of tibial alignment - Finite element analysis of tibial malalignment [J].
Perillo-Marcone, A ;
Barrett, DS ;
Taylor, M .
JOURNAL OF ARTHROPLASTY, 2000, 15 (08) :1020-1027