Flow-injection analysis spectrophotometric determination of bismuth in environmental and pharmaceutical samples

被引:7
作者
Agrawal, K
Mundhara, GL
Patel, KS [1 ]
Hoffmann, P
机构
[1] Ravishankar Univ, Sch Studies Chem, Raipur 492010, Madhya Pradesh, India
[2] Tech Univ Darmstadt, D-64287 Darmstadt, Germany
关键词
flow-injection analysis; spectrophotometry; bismuth; cationic surfactant; environmental and pharmaceutical materials;
D O I
10.1081/AL-200026693
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, simple, rapid, selective, and sensitive flow-injection analysis (FIA) method for the spectrophotometric determination of Bi is described. It is based on reaction of Bi (III) with I- ions in the presence of cationic surfactants (CS), i.e., cetylpyridinium chloride, cetyltrimethylammonium bromide, tetradecyltrimethylarnmonium bromide, dodecyltrimethylarnmonium bromide in sulfuric media to give a violet-colored complex. The apparent value of molar absorpitivity of the complex in the terms of Bi with four CSs lie in the range of (1.00-1.20) x 10(4) Lmol(-1)cm(-1) at lambda(max) 490 nm. Among them, the most sensitive CSs, i.e., cetylpyridinium chloride (CPC) has been selected for the detailed studies. The detection limit (causing absorbance > 3 sec) of the method is 65 mug L-1 Bi. The sample throughput of the method is > 120 samples hr(-1). The effect of diverse ions and surfactants in the FIA determination of Bi is examined. The composition of the complex is discussed. The analytical and FIA variables in the determination of Bi are optimized. The method has been applied for analysis of Bi in the environmental and pharmaceutical materials.
引用
收藏
页码:2163 / 2174
页数:12
相关论文
共 12 条
[1]   Determination of bismuth in pharmaceutical products using liquid-liquid extraction in a flow injection system [J].
Alonso, A ;
Almendral, MJ ;
Báez, MD ;
Porras, MJ ;
Lávin, FL ;
de María, CG .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :129-133
[2]  
Barakat SA, 2002, TURK J CHEM, V26, P345
[3]  
BURNS DT, 1989, ANAL CHIM ACTA, V225, P449
[4]  
DANBY R, 1990, GBC AUTOMATIC HYBRID
[5]  
*EUR COMM VET MED, 1997, EUR AG EV MED PROD
[6]   Automated flow injection system for the preconcentration of bismuth and lead from acid solutions of alloys and determination by electrothermal atomic absorption spectrometry [J].
Giacomelli, MBO ;
Ganzarolli, EM ;
Curtius, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (05) :525-533
[7]   Determination of bismuth in cod muscle, lake and river sediment by flow injection on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry [J].
Ivanova, E ;
Yan, XP ;
Adams, F .
ANALYTICA CHIMICA ACTA, 1997, 354 (1-3) :7-13
[8]  
LEONARD N, 1957, J AM CHEM SOC, V79, P4576
[9]   On-line preconcentration system for bismuth determination in urine by flow injection hydride generation inductively coupled plasma atomic emission spectrometry [J].
Moyano, S ;
Wuilloud, RG ;
Olsina, RA ;
Gásquez, JA ;
Martinez, LD .
TALANTA, 2001, 54 (02) :211-219
[10]   EXTRACTION FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF BISMUTH WITH LEAD TETRAMETHYLENEDITHIOCARBAMATE [J].
SZPUNARLOBINSKA, J .