Uterine leiomyomas: MR imaging-guided focused ultrasound surgery - Results of different treatment protocols

被引:179
作者
Fennessy, Fiona M.
Tempany, Clare M.
McDannold, Nathan J.
So, Minna J.
Hesley, Gina
Gostout, Bobbie
Kim, Hyun S.
Holland, George A.
Sarti, Dennis A.
Hynynen, Kullervo
Jolesz, Ferenc A.
Stewart, Elizabeth A.
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Obstet & Gynecol, Boston, MA 02115 USA
[3] Mayo Clin & Mayo Fdn, Dept Radiol, Rochester, MN 55905 USA
[4] Mayo Clin & Mayo Fdn, Dept Obstet & Gynecol, Rochester, MN 55905 USA
[5] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[6] Lahey Clin Fdn, Dept Radiol, Burlington, MA USA
[7] Radnet Management, Los Angeles, CA USA
关键词
THERMAL DOSIMETRY; FIBROID TUMORS; CHEMICAL-SHIFT; IN-VIVO; THERAPY; FEASIBILITY; TEMPERATURE; THERMOMETRY; ABLATION; SYMPTOM;
D O I
10.1148/radiol.2433060267
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively assess patient response (after 12 months) to magnetic resonance (MR) imaging-guided focused ultrasound surgery in treatment of uterine leiomyomas by using two treatment protocols. Materials and Methods: This prospective clinical trial was approved by institutional review boards and was HIPAA compliant. After giving informed consent, patients with symptomatic leiomyomas were consecutively enrolled and treated at one of five U. S. centers by using an original or a modified protocol. Outcomes were assessed with the symptom severity score (SSS) obtained at baseline and 3, 6, and 12 months after treatment. Adverse events (AEs) were recorded. Statistical analysis included Student t test, Fisher exact test, analysis of covariance, Spearman correlation, and logistic regression. Results: One hundred sixty patients had a mean SSS of 62.1 +/- 16.3 (standard deviation) at baseline, which decreased to 35.5 +/- 19.5 at 3 months (P < .001) and to 32.3 +/- 19.8 at 6 months (P < .001) and was 32.7 +/- 21.0 at 12 months (P < .001). Ninety-six patients (mean age, 46.0 years +/- 4.6) were treated with an original protocol, and 64 (mean age, 45.9 years +/- 3.9) were treated with a modified protocol. Patients in the modified group had a significantly greater SSS decrease at 3 months (P = .037) than those in the original group, and 73% of those in the original group and 91% of those in the modified group reported a significant decrease in SSS (of 10 points or greater) at 12 months. No serious AEs were recorded. Fewer AEs were reported in the modified group than in the original group (25% vs 13% reporting no event). Of evaluable patients, fewer in the modified group chose alternative treatment (28%) than in the original group (37%). Conclusion: MR imaging-guided focused ultrasound surgery results in symptomatic improvement, sustained to 12 months after treatment. Treatment with a modified protocol results in greater clinical effectiveness and fewer AEs.
引用
收藏
页码:885 / 893
页数:9
相关论文
共 19 条
[1]   Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging [J].
Chung, AH ;
Jolesz, FA ;
Hynynen, K .
MEDICAL PHYSICS, 1999, 26 (09) :2017-2026
[2]   Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam [J].
Chung, AH ;
Hynynen, K ;
Colucci, V ;
Oshio, K ;
Cline, HE ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :745-752
[3]   FOCUSED US SYSTEM FOR MR IMAGING-GUIDED TUMOR ABLATION [J].
CLINE, HE ;
HYNYNEN, K ;
WATKINS, RD ;
ADAMS, WJ ;
SCHENCK, JF ;
ETTINGER, RH ;
FREUND, WR ;
VETRO, JP ;
JOLESZ, FA .
RADIOLOGY, 1995, 194 (03) :731-737
[4]   MRI guidance of focused ultrasound therapy of uterine fibroids: Early results [J].
Hindley, J ;
Gedroyc, WM ;
Regan, L ;
Stewart, E ;
Tempany, C ;
Hynnen, K ;
Macdanold, N ;
Inbar, Y ;
Itzchak, Y ;
Rabinovici, J ;
Kim, K ;
Geschwind, JF ;
Hesley, G ;
Gostout, B ;
Ehrenstein, T ;
Hengst, S ;
Sklair-Levy, M ;
Shushan, A ;
Jolesz, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (06) :1713-1719
[5]   Thermal effects of focused ultrasound on the brain: Determination with MR imaging [J].
Hynynen, K ;
Vykhodtseva, NI ;
Chung, AH ;
Sorrentino, V ;
Colucci, V ;
Jolesz, FA .
RADIOLOGY, 1997, 204 (01) :247-253
[6]   A clinical, noninvasive, MR imaging monitored ultrasound surgery method [J].
Hynynen, K ;
Freund, WR ;
Cline, HE ;
Chung, AH ;
Watkins, RD ;
Vetro, JP ;
Jolesz, FA .
RADIOGRAPHICS, 1996, 16 (01) :185-195
[7]   PRECISE AND FAST TEMPERATURE MAPPING USING WATER PROTON CHEMICAL-SHIFT [J].
ISHIHARA, Y ;
CALDERON, A ;
WATANABE, H ;
OKAMOTO, K ;
SUZUKI, Y ;
KURODA, K ;
SUZUKI, Y .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :814-823
[8]   Calibration of water proton chemical shift with temperature for noninvasive temperature imaging during focused ultrasound surgery [J].
Kuroda, K ;
Chung, AH ;
Hynynen, K ;
Jolesz, FA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :175-181
[9]   Full thickness abdominal burn following magnetic resonance guided focused ultrasound therapy [J].
Leon-Villapalos, J ;
Kaniorou-Larai, M ;
Dziewulski, P .
BURNS, 2005, 31 (08) :1054-1055
[10]   A new method for the generation and use of focused ultrasound in experimental biology [J].
Lynn, JG ;
Zwemer, RL ;
Chick, AJ ;
Miller, AE .
JOURNAL OF GENERAL PHYSIOLOGY, 1942, 26 (02) :179-193