ABTS-Multiwalled Carbon Nanotubes Nanocomposite/Bi Film Electrode for Sensitive Determination of Cd and Pb by Differential Pulse Stripping Voltammetry

被引:73
作者
Deng, Wenfang [1 ]
Tan, Yueming [1 ]
Fang, Zhengfa [1 ]
Xie, Qingji [1 ]
Li, Yunyong [1 ]
Liang, Xiaoling [1 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Normal Univ, Key Lab Chem Biol & Tradit Chinese Med Res, Minist Educ China, Coll Chem & Chem Engn, Changsha 410081, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
2,2 '-Azinobis(3-ethylbenzothiazoline-6-sulfonate) diammonium salt (ABTS); Multiwalled carbon nanotubes (MWCNTs); Bismuth film electrode (BiFE); Differential pulse stripping voltammetry (DPSV); Pb2+; Cd2+; Voltammetry; Nanotube; HEAVY-METAL IONS; AQUEOUS-SOLUTION; TRACE-METALS; ADSORPTION; MERCURY; FABRICATION; REDUCTION; CADMIUM; ZN;
D O I
10.1002/elan.200900207
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A 2,2'-azinobis (3-ethylbenzothiazoline-6-sulfonate) diammonium salt (ABTS)-multiwalled carbon nanotubes (MWCNTs) nanocomposite/Bi film modified glassy carbon (GC) electrode was constructed for the differential pulse stripping voltammetric determination of trace Pb2+ and Cd2+. This electrode was more sensitive than ABTS-free Bi/GC and Bi/MWCNTs/GC electrodes. Linear responses were obtained in the range from 0.5 to 35 mu g L-1 for Cd2+ and 0.2 to 50 mu g L-1 Pb(II), with detection limits of 0.2 mu g L-1 for Cd2+ and 0.1 mu g L-1 for Pb2+, respectively. This sensor was applied to the simultaneous detection of Cd2+ and Pb2+ in water samples with satisfactory recovery.
引用
收藏
页码:2477 / 2485
页数:9
相关论文
共 60 条
[1]   Carbon nanotube composite coated platinum electrode for detection of Cr(III) in real samples [J].
Abbaspour, Abdolkarim ;
Izadyar, Anahita .
TALANTA, 2007, 71 (02) :887-892
[2]   Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodes [J].
Baldrianova, L. ;
Svancara, I. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2007, 599 (02) :249-255
[3]   Effect of Bi(III) concentration on the stripping voltammetric response of in situ bismuth-coated carbon paste and gold electrodes [J].
Baldrianova, L. ;
Svancara, I. ;
Vlcek, M. ;
Economou, A. ;
Sotiropoulos, S. .
ELECTROCHIMICA ACTA, 2006, 52 (02) :481-490
[4]   Eighty years of polarography - History and future [J].
Barek, J ;
Zima, J .
ELECTROANALYSIS, 2003, 15 (5-6) :467-472
[5]   Sensitive determination of Cd and Pb by differential pulse stripping voltammetry with in situ bismuth-modified zeolite doped carbon paste electrodes [J].
Cao, Linyuan ;
Jia, Jianbo ;
Wang, Zhenhui .
ELECTROCHIMICA ACTA, 2008, 53 (05) :2177-2182
[6]   Thiol-Functionalized Silica Thin Film Modified Electrode in Determination of Mercury Ions in Natural Water [J].
Cesarino, Ivana ;
Gomes Cavalheiro, Eder Tadeu .
ELECTROANALYSIS, 2008, 20 (21) :2301-2309
[7]   Adsorption of Ni(II) from aqueous solution using oxidized multiwall carbon nanotubes [J].
Chen, Changlun ;
Wang, Xiangke .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (26) :9144-9149
[8]   Voltammetric detection of cadmium ions at glutathione-modified gold electrodes [J].
Chow, E ;
Hibbert, DB ;
Gooding, JJ .
ANALYST, 2005, 130 (06) :831-837
[9]   Nanotube nanodevice [J].
Collins, PG ;
Zettl, A ;
Bando, H ;
Thess, A ;
Smalley, RE .
SCIENCE, 1997, 278 (5335) :100-103
[10]   Storage of hydrogen in single-walled carbon nanotubes [J].
Dillon, AC ;
Jones, KM ;
Bekkedahl, TA ;
Kiang, CH ;
Bethune, DS ;
Heben, MJ .
NATURE, 1997, 386 (6623) :377-379