Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability

被引:303
作者
Ricci, F
Amine, A
Palleschi, G
Moscone, D [1 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] Univ Hassan II Mohammadia, Fac Sci & Tech, Mohammadia, Morocco
关键词
Prussian Blue; screen printed electrodes; H2O2; determination; oxidase biosensors;
D O I
10.1016/S0956-5663(02)00169-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The promising advantages of Prussian Blue (PB) as catalyst and of the thick film screen printing technology have been combined to assemble sensors with improved characteristics for the amperometric determination of H2O2, PB-modified screen printed electrodes were applied to detect H2O2 at an applied potential of -0.05 V versus the internal screen printed Ag pseudoreference electrode, showing a detection limit Of 10(-7) Mol 1(-1), a linearity range from 10(-7) to 5 x 10(-5) mol 1(-1), a sensitivity of 234 muA mmol 1(-1) cm(-2), and a high selectivity. Improved stability at alkaline pH values was also observed, which made possible their use with enzymes having an optimum basic pH. Then, the immobilisation of a single enzyme (glucose oxidase (GOD) or choline oxidase (ChOX)) or of two enzymes, acetylcholinesterase (AchE) coimmobilised with ChOX, has been performed on the surface of PB modified screen-printed electrodes (SPEs) using glutaraldehyde and Nafion((R)). ChOX has been selected as an example of enzyme working at alkaline pH. The choline biosensors showed a detection limit of 5 X 10-7 Mol 1(-1), a wide linearity range (5 x 10-7 10(-4) Mol 1(-1)), a high selectivity and a remarkable long term stability of 9 months at 4 degreesC, and at least 4 weeks at room temperature. Similar analytical characteristics and stability were observed with the acetylcholine biosensors. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 41 条
[1]   Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[2]  
[Anonymous], [No title captured]
[3]   DISPOSABLE RUTHENIZED SCREEN-PRINTED BIOSENSORS FOR PESTICIDES MONITORING [J].
CAGNINI, A ;
PALCHETTI, I ;
LIONTI, I ;
MASCINI, M ;
TURNER, APF .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :85-89
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[6]   Estimation of soluble L-lactate in dairy products using screen-printed sensors in a flow injection analyser [J].
Collier, WA ;
Lovejoy, P ;
Hart, AL .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :219-225
[7]   Self-gelatinizable copolymer immobilized glucose biosensor based on Prussian Blue modified graphite electrode [J].
Deng, Q ;
Li, B ;
Dong, SJ .
ANALYST, 1998, 123 (10) :1995-1999
[8]  
Frew J. E., 1987, ANAL CHEM, V59, p933A
[9]   Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) :122-128
[10]   Electrocatalytic reactions of hydrogen peroxide at carbon paste electrodes modified by some metal hexacyanoferrates [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (03) :236-241