Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability

被引:303
作者
Ricci, F
Amine, A
Palleschi, G
Moscone, D [1 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] Univ Hassan II Mohammadia, Fac Sci & Tech, Mohammadia, Morocco
关键词
Prussian Blue; screen printed electrodes; H2O2; determination; oxidase biosensors;
D O I
10.1016/S0956-5663(02)00169-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The promising advantages of Prussian Blue (PB) as catalyst and of the thick film screen printing technology have been combined to assemble sensors with improved characteristics for the amperometric determination of H2O2, PB-modified screen printed electrodes were applied to detect H2O2 at an applied potential of -0.05 V versus the internal screen printed Ag pseudoreference electrode, showing a detection limit Of 10(-7) Mol 1(-1), a linearity range from 10(-7) to 5 x 10(-5) mol 1(-1), a sensitivity of 234 muA mmol 1(-1) cm(-2), and a high selectivity. Improved stability at alkaline pH values was also observed, which made possible their use with enzymes having an optimum basic pH. Then, the immobilisation of a single enzyme (glucose oxidase (GOD) or choline oxidase (ChOX)) or of two enzymes, acetylcholinesterase (AchE) coimmobilised with ChOX, has been performed on the surface of PB modified screen-printed electrodes (SPEs) using glutaraldehyde and Nafion((R)). ChOX has been selected as an example of enzyme working at alkaline pH. The choline biosensors showed a detection limit of 5 X 10-7 Mol 1(-1), a wide linearity range (5 x 10-7 10(-4) Mol 1(-1)), a high selectivity and a remarkable long term stability of 9 months at 4 degreesC, and at least 4 weeks at room temperature. Similar analytical characteristics and stability were observed with the acetylcholine biosensors. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 41 条
[21]   ELECTROCHEMISTRY OF PRUSSIAN BLUE MODIFIED ELECTRODES - AN ELECTROCHEMICAL PREPARATION METHOD [J].
ITAYA, K ;
AKAHOSHI, H ;
TOSHIMA, S .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (07) :1498-1500
[22]   Novel hexacyanoferrate(III) modified graphite disc electrodes and their application in enzyme electrodes .1. [J].
Jaffari, SA ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :1-9
[23]   The electrocatalytic activity of Prussian blue in hydrogen peroxide reduction studied using a wall-jet electrode with continuous flow [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 456 (1-2) :97-104
[24]  
Karyakin AA, 2001, ELECTROANAL, V13, P813, DOI 10.1002/1521-4109(200106)13:10<813::AID-ELAN813>3.0.CO
[25]  
2-Z
[26]   Prussian-Blue-based amperometric biosensors in flow-injection analysis [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
TALANTA, 1996, 43 (09) :1597-1606
[27]   Amperometric biosensor for glutamate using Prussian Blue-based "artificial peroxldase" as a transducer for hydrogen peroxide [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1720-1723
[28]   PRUSSIAN BLUE BASED FIRST-GENERATION BIOSENSOR - A SENSITIVE AMPEROMETRIC ELECTRODE FOR GLUCOSE [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2419-2423
[29]   Construction and analytical characterization of Prussian Blue-based carbon paste electrodes and their assembly as oxidase enzyme sensors [J].
Moscone, D ;
D'Ottavi, D ;
Compagnone, D ;
Palleschi, G ;
Amine, A .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2529-2535