摘要
This paper reports on the development and characterization of Prussian Blue-modified carbon paste electrodes. New methods of matrix modification with Prussian Blue are reported. Two different carbon pastes have been prepared, using mineral oil or solid paraffin, thus obtaining different types of sensors whose behavior toward the electrochemical reduction of hydrogen peroxide has been fully characterized. Results obtained with Prussian Blue-modified electrodes showed a long operational lifetime, an excellent stability in a nide range of pH (3-9), a high sensitivity, and a fast response time. In addition, the coupling of solid carbon paste modified with Prussian Blue and the enzymes glucose oxidase and choline oxidase led to the assembling of biosensors that showed an optimum working range at alkaline pH.
引用
收藏
页码:2529 / 2535
页数:7
相关论文
共 43 条
[1]   CYANIDE DETERMINATION USING AN AMPEROMETRIC BIOSENSOR BASED ON CYTOCHROME-OXIDASE INHIBITION [J].
AMINE, A ;
ALAFANDY, M ;
KAUFFMANN, JM ;
PEKLI, MN .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2822-2827
[2]   AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ .
TALANTA, 1991, 38 (01) :107-110
[3]  
BERGER R, 1983, PEDIATR INFECT DIS J, V2, P172
[4]   VOLTAMMETRIC BEHAVIOR OF PERBORATE ON PRUSSIAN-BLUE-MODIFIED CARBON PASTE ELECTRODES [J].
BOYER, A ;
KALCHER, K ;
PIETSCH, R .
ELECTROANALYSIS, 1990, 2 (02) :155-161
[5]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[6]  
Compagnone D, 1998, ANAL LETT, V31, P1107
[7]   Self-gelatinizable copolymer immobilized glucose biosensor based on Prussian Blue modified graphite electrode [J].
Deng, Q ;
Li, B ;
Dong, SJ .
ANALYST, 1998, 123 (10) :1995-1999
[8]   Operational stability of amperometric hydrogen peroxide sensors, based on ferrous and copper hexacyanoferrates [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :93-97
[9]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[10]   TUNGSTEN-OXIDE PRUSSIAN BLUE ELECTROCHROMIC SYSTEM BASED ON A PROTON-CONDUCTING POLYMER ELECTROLYTE [J].
HO, KC ;
RUKAVINA, TG ;
GREENBERG, CB .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1994, 141 (08) :2061-2067