The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit - Finite-element analysis

被引:712
作者
Polikeit, A [1 ]
Nolte, LP [1 ]
Ferguson, SJ [1 ]
机构
[1] Univ Bern, ME Muller Inst Biomech, CH-3010 Bern, Switzerland
关键词
cement augmentation; finite-element analysis; lumbar spine; stress distribution; vertebroplasty;
D O I
10.1097/00007632-200305150-00006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The effect of cement augmentation on an osteoporotic lumbar functional spinal unit was investigated using finite-element analysis. Objective. To evaluate the influence of cement augmentation on load transfer, stresses, and strains. Summary of Background Data. Osteoporosis is the most frequent skeletal disease of the elderly, leading to weakness of the bony structures. Cement injection into vertebral bodies has been used to treat osteoporotic compression fractures of the spine. The clinical results are encouraging. Experimental biomechanical studies showed significant increases in stiffness and strength of treated bodies. However, little is known about the consequences for the adjacent, nontreated levels. Methods. Three-dimensional finite-element models of L2-L3 were developed and the material properties adapted to simulate osteoporosis. The influence of augmentation level as well as uni- and bipedicular filling with polymethylmethacrylate were investigated. Compression, flexion, and lateral bending were simulated. Results. Augmentation increased the pressure in the nucleus pulposus and the deflection of the adjacent end-plate. The stresses and strains in the vertebrae next to an augmentation were increased, and their distribution was changed. Larger areas were subjected to higher stresses and strains. The treatment clearly altered the load transfer. Changes to the overall stress and strain distribution were less pronounced for unipedicular augmentation. Conclusions. Cement augmentation restores the strength of treated vertebrae, but leads to increased end-plate bulge and an altered load transfer in adjacent vertebrae. This supports the hypothesis that rigid cement augmentation may facilitate the subsequent collapse of adjacent vertebrae. Further study is required to determine the optimal reinforcement material and filling volume to minimize this effect.
引用
收藏
页码:991 / 996
页数:6
相关论文
共 35 条
[1]
BAROUD G, 2001, 9 ANN S COMP METH OR
[2]
The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[3]
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1542-1546
[4]
Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[5]
DEFORMATION OF THE VERTEBRAL ENDPLATE UNDER AXIAL LOADING OF THE SPINE [J].
BRINCKMANN, P ;
FROBIN, W ;
HIERHOLZER, E ;
HORST, M .
SPINE, 1983, 8 (08) :851-856
[6]
FERGUSON S, 2001, P 47 ANN M ORTH RES
[7]
GALIBERT P, 1987, NEUROCHIRURGIE, V33, P166
[8]
New technologies in spine - Kyphoplasty and vertebrosplasty for the treatment of painful osteoporotic compression fractures [J].
Garfin, SR ;
Yuan, HA ;
Reiley, MA .
SPINE, 2001, 26 (14) :1511-1515
[9]
GOEL VK, 1993, SPINE, V18, P1531
[10]
Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty [J].
Grados, F ;
Depriester, C ;
Cayrolle, G ;
Hardy, N ;
Deramond, H ;
Fardellone, P .
RHEUMATOLOGY, 2000, 39 (12) :1410-1414