Comparison of defects in ProTaper hand-operated and engine-driven instruments after clinical use

被引:28
作者
Cheung, G. S. P.
Bian, Z.
Shen, Y. [1 ]
Peng, B.
Darvell, B. W.
机构
[1] Wuhan Univ, Lab Oral Biomed Engn, Minist Educ, Sch Stomatol, Wuhan, Peoples R China
[2] Univ Hong Kong, Fac Dent, Dept Endodont, Hong Kong, Hong Kong, Peoples R China
关键词
fatigue; fracture; nickel-titanium; ProTaper; rotary instrument; shear;
D O I
10.1111/j.1365-2591.2006.01200.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the type of defects and mode of material failure of engine-driven and hand-operated ProTaper instruments after clinical use. Methodology A total of 401 hand-operated and 325 engine-driven ProTaper instruments were discarded from an endodontic clinic over 17 months. Those that had fractured were examined for plastic deformation in lateral view and remounted for fractographical examination in scanning electron microscope. The mode of fracture was classified as 'fatigue' or 'shear' failure. The lengths of fractured segments in both instruments were recorded. Any distortion in hand instrument was noted. Data were analysed using chi-square, Fisher's exact or Student's t-test, where appropriate. Results Approximately 14% of all discarded hand-operated instruments and 14% of engine-driven instruments were fractured. About 62% of hand instruments failed because of shear fracture, compared with approximately 66% of engine-driven instruments as a result of fatigue (P < 0.05). Approximately 16% of hand instruments were affected by shear, and either remained intact or was fractured, compared with 5% of engine-driven instruments (P < 0.05). The length of the broken fragment was significantly shorter in hand versus engine-driven group (P < 0.05). Approximately 7% of hand instruments were discarded intact but distorted (rarely for engine-driven instruments); all were in the form of unscrewing of the flutes. The location of defects in hand Finishing instruments was significantly closer to the tip than that for Shaping instruments (P < 0.05). Conclusions Under the conditions of this study (possibly high usage), the failure mode of ProTaper engine-driven and hand-operated instruments appeared to be different, with shear failure being more prevalent in the latter.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 40 条
[1]   SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Nusstein, JM ;
Daehn, GS .
JOURNAL OF ENDODONTICS, 2005, 31 (01) :40-43
[2]   K3 endo, ProTaper, and ProFile systems: Breakage and distortion, in severely curved roots of molars [J].
Ankrum, MT ;
Hartwell, GR ;
Truitt, JE .
JOURNAL OF ENDODONTICS, 2004, 30 (04) :234-237
[3]  
ASM International, 1987, ASM HDB, V12
[4]   Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals [J].
Bahia, MGA ;
Buono, VTL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 100 (02) :249-255
[5]   The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses [J].
Barbakow, F ;
Lutz, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :46-50
[6]  
Bergmans L, 2001, AM J DENT, V14, P324
[7]   Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile [J].
Berutti, E ;
Chiandussi, G ;
Gaviglio, I ;
Ibba, A .
JOURNAL OF ENDODONTICS, 2003, 29 (01) :15-19
[8]  
Blatt FrankJ., 1992, MODERN PHYS
[9]   Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments [J].
Blum, JY ;
Cohen, A ;
Machtou, P ;
Micallef, JP .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (01) :24-31
[10]   Defects in ProTaper S1 instruments after clinical use: fractographic examination [J].
Cheung, GSP ;
Peng, B ;
Bian, Z ;
Shen, Y ;
Darvell, BW .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (11) :802-809